CoolPower MPS35
7

Using the mains rectifier

Warning!
e
Do not reverse the polarity. If the poles are reversed device may
overheat and be damaged.
Caution!
e
Replace defective fuses with new ones of the same rating (15 A
slow-blow).
Caution!
e
Protect the positive connecting cable to the battery by an external
fuse of 10 A (fig. 2 4, page 3).
Insert the fuse as near as possible to the battery.
➤ Determine the required cross section of the cable in relation to the cable
length according to fig. 3, page 3.
Key for fig. 3, page 3
Co-ordinate axis
l
➤ Connect the mains rectifier according to the circuit diagram in fig. 2,
page 3.
Key for fig. 2, page 3:
Item
Explanation
1
Mains cable
2
Battery input terminals
3
Compressor output terminals
4
Fuse (not included in scope of delivery)
5
Battery
rt
red
sw
black
Meaning
Cable length
Cable cross section
Using the mains rectifier
Unit
m
mm²
17