Installation Instructions; And; Description Of The Unit; Operation - Stiebel Eltron HTE 4 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
1. Operation instructions

1.1 Description of the unit

The automatically operating Stiebel Eltron
HTE 4 A and HTE 5 A electronic hand
dryers are fitted with a proximity switch
which activates the fan when your hands are
brought towards it, (approximately 60 - 120
mm below the warm air exit grille). The dryer
automatically switches off approximately 3
seconds after the hands have moved away
from the sensor.
The casing design does not allow cigarettes
or drinks etc to be placed on top, causing a
hazard. To retain this feature, when
assembling ensure that there are no gaps
between the wall and the unit.
In addition, the HTE 5 A is protected against
damage by the cast aluminium casing.

2. Installation instructions

2.1 Configuration

1 Outer casing
2 Appliance
3 Warm–air exit grille
4 Fastening screws
5 Cable grommet
6 Mounting holes
7 Locking bolt
8 PVC-angle (only for HTE 5 A)
9 Fan
10 Heating element
11 Sensor
12 Capacitor

2.2 Technical data

HTE 4 A
Weight
2,5 kg
Engine performance
Nominal output
Voltage
220 V - 240 V, 60 Hz
Loading information and technical data may
vary from country to country. Please note
the information from the rating plate for
specific details.
2.3 Regulations and
specifications
! All electrical installation work should be
carried out by a qualified electrician in
accordance with IEE regulations.
! The appliance must be separable from the
mains with an appropriate multipole device
with an air break of at least 3 mm.
Concerning this point a protective device,
line switch, fuses etc can be installed.
! This appliance must be installed (electrical
installation), commissioned and serviced by
26
for the user and the professional

1.2 Operation

In order to save energy and shorten the
drying time, vigorously shake wet hands over
the washbasin, then hold your hands beneath
the air exit grille rubbing them together in
the warm airstream.

1.3 Safety notes

During operation, temperatures of
over 90 °C can occur at the warm-
air exit grille. Due to the risk of
overheating this should not be covered.
In the event of overheating the temperature
safety cut out switches off the heating
element and the fan continues to run in a
cooling mode. The heating element switches
back on after approximately two minutes.
Ensure that the air inlet grilles on the
underside and rear of the dryer are always
kept open.
for the professional
approved service technicians in accordance
with these instructions.
! Any maintenance to the hand dryer should
be carried out by a qualified electrician. The
power supply should be disconnected
before removing the front cover. Only ori-
ginal Stiebel Eltron parts should be used.

2.4 Installation

The hand dryer should only be mounted on
a solid wall.
To install the unit follow these instructions:
2.4.1 Removal of front cover
HTE 4 A (see page 3)
a. Remove the mounting screws (4).
HTE 5 A
b. Pull down the locking bolt (7).
4 kg
c. Remove the front cover (1).
70 W
HTE 5 A (see page 30)
1800 W
a. Remove the mounting screw (4).
b. Pull down the locking bolt (7).
c. Slide off the outer casing (1).
2.4.2 Wall mounting
a. Transfer the four mounting points to the
wall using the drilling template and drill the
mounting holes. Note the length and
position of the power supply lead.
b. Draw the power supply lead through the
cable grommet (5) at the rear panel of the
dryer.
c. Screw the appliance (2) to the wall.
2.4.3 Electrical Connection
The dryer is designed only for permanent
connection to 220 V – 240 V~ 60 Hz alter-
nating current.
Please observe the rating plate!
Trouble-free function and operational safety
can only be guaranteed if the original Stiebel
Eltron accessories and spare parts are used.

1.4 Care

When cleaning the casing, only use a soft
cloth, with a mild detergent if necessary, and
repolish with a soft cloth. Do not spray the
dryer with water or use any abrasive or
caustic cleaning agents.

1.5 Trouble-shooting

Like all proximity switches, the operation of
the sensor is impaired if it is covered. If this
happens the hand dryer automatically
switches off after 3 seconds preventing it
from running continuously. In the event of an
operating failure, check that the sensor has
not been covered. After the removal of any
objects the dryer should function as normal.
The PVC-angle (8) piece fixed in the
metalcase of the HTE 5 A provides
insulation for the electric connection.
The voltage shown on the rating plate must
agree with the supply voltage. Cable should
be correctly sized in accordance with the
loading of the appliance.
The electrical connection must be done
strictly according to the wiring diagram.
I.
II.
The wiring diagrams on pages 3 and 30 are
not valid for the HTE - A !
The power supply cable must not be
located in the vicinity of the fan motor.
The maximum lenght of the cable
must not exceed 20 cm.
9
10
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hte 5

Table des Matières