Installation:

The Heating Unit must be mounted in a vertical
Water circuit (min. ½", max. ¾") has to be installed according to the following:
( 3)
Install non-return valve
(18) Install
water filter
Install automatic vent valve: must be at highest point of circuit in a
( 7)
frost-protected-room (black knurled screw has to be in open position!)
( 6) Install
safety valve
(16)
Install SUEVIA Drinking Bowls into the circuit connected at the top and the bottom
(10) Install
relief valve
(11) Install
shut-off valve
(13)
Install manual ventilation valve
( 8)
Mount non-return flap with compression couplings (by customer),
minimum distance from heating apparatus 0,5m - maximal 1,0 m -> note direction flow!
(17)
Install Flow control Ref. 101.0309
( 9)
Install return flow temperature sensor
(19)
Mount heating cable in non-Frost-protected areas or in draughty locations.
(14)
Insulate pipes minimum thickness 30 mm, heat conductivity
(15)
Mount bite protection
(12) I
nstall residual-current protective device.
System must be used with a separate 30 mA residual-current protective device (RCD)
Unit location:
Installation must be in a dry, frost- and draught-protected room and at an accessible height.
Pipe insulation:
Insulation of complete pipe system is indispensible,
-> minimum thickness 30 mm, heat conductivity
Water line has to be insulated against condensation water and heat loss.
Water connection:
Water entrance ¾", Circuit piping min. ½", max. ¾",
Water pressure has to be between min.1 bar ( 14 psi) - max.4 bar (58 psi)!
If water pressure is lower than recommended, install a pressure accumulator.
If water pressure is higher than recommended, install a pressure reduction valve.
Circuit length
:
Length of the insulated water tube system incl. all return pipes should not exceed 200 m!
Circulation pump
:
Circulation pump must run on positon 3.
Circulation pump has to be bled.
The height difference between entry and return pipeline should not exceed 5 meters.
Functional capability of Circulation pump has to be constantly checked!
Application field:
SUEVIA Heating Unit Pulstronic 2011 Mod. 313 is exclusively thought to keep water pipes
frost-free in stables for animals.
It can only be used for warming up water, other liquids are not allowed!
16
Installation
position on the wall!
W
0,04 /
mK
W
0,04 /
mK
.