Technical Features; Wall Mounting; Recessed Installation - CAME PLACO-C Manuel D'installation

Masquer les pouces Voir aussi pour PLACO-C:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
70
Terminal boards
70
EN
4
A
Installation
The power supplier must ALWAYS be installed vertically.
The unit can be installed on a DIN guide (EN 50022) in a special electrical panel.
For the overall dimensions, see fig. 1.
43,5
Provide sufficient ventilation if the power supplier is installed in a container.
7,5
57
1
B
~
64,5
~
+
(*) The unit is protected against overloads and
short circuits.
M1
M2
+

Wall mounting

With the Allen wrench, unscrew the blocking screws and remove the plate (figure 1). Fix the given plugs and
screw the entry panel (figure 2) at the desired height. Run the sheath with the system conductors as shown
in figure 2.
Extract the plastic terminal cover and wire the connections (figure 3). Once all the connections have been
made, re-insert the terminal covers. Install the front plate (figure 1).
1

Recessed installation

Install the recessed box at the desired, but in advance, run the sheath with the system conductors through one
of the breaking points (figure 4 point A).
During installation of the recessed box it is possible to avoid any deformation by using the provided spacer
(figure 4 point B).
With the Allen wrench, unscrew the blocking screws and remove the entry panel plate (figure 1).
Introduce the cable connections in the special hole (figure 2) and fix the entry panel on the frame as shown in
figure 5; extract the plastic terminal cover and wire the connections (figure 3).
Once all the connections have been made, re-insert the terminal covers.
Install the front plate (figure 1).
2
3
VAS/101-CM
Mains
18 VDC power supply (*)
PLACO-C
B
A

Technical features

Power supply: 230 VAC 50-60 Hz
I
max
Current absorbed
AC
Power dissipated: 10 W max
Rated power supply: 18 VDC 1 A-0.5 A 1'/3'
Dimensions: 4 DIN
Storage temperature: -25 °C + 70 °C
Operating temperature: 0 °C +35 °C
IP degree: IP 30
4
200 mA
AC
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bianca-c001ck0001

Table des Matières