Hot Water Output; Application Areas/Conversion Table; Fault Conditions - Stiebel Eltron DHC-E 3/3.5-1 Trend Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION

17.3 Hot water output

The domestic hot water (DHW) output is subject to the connected
power supply, the water heater's connected load, and the cold water
inlet temperature. The rated voltage and rated output can be found
on the type plate.
Power output in kW
Rated voltage
Model
DHC-E
3.0
3/3.5-1
Trend
3.5
2.9
DHC-E
4.5
4/6-2
3.8
Trend
6.0
5.4
DHC-E
7.2
8/10-2
7.2
Trend
9.6
9.0
DHC-E
12/15-2
10.8
Trend &
12.0
Plus
14.4
Power output in kW
Rated voltage
Model
DHC-E
3.0
3/3.5-1
Trend
3.5
2.9
DHC-E
4.5
4/6-2
3.8
Trend
6.0
5.4
DHC-E
7.2
8/10-2
7.2
Trend &
Plus
9.6
9.0
DHC-E
12/15-2
10.8
Trend &
12.0
Plus
14.4
24
| DHC-E Trend & DHC-E Plus
100 °F DHW output in gpm
Cold water inlet temperature
41 °F
50 °F
59 °F
68 °F
0.35
0.41
0.5
0.64
0.41
0.48
0.58
0.75
0.34
0.4
0.48
0.62
0.52
0.61
0.75
0.96
0.44
0.52
0.63
0.81
0.69
0.82
1.0
1.28
0.63
0.74
0.9
1.15
0.83
0.98
1.2
1.54
0.83
0.98
1.2
1.54
1.11
1.31
1.6
2.05
1.04
1.23
1.5
1.92
1.24
1.46
1.78
2.28
1.39
1.64
2.0
2.56
1.67
1.97
2.4
3.07
122 °F DHW output in gpm
Cold water inlet temperature
41 °F
50 °F
59 °F
68 °F
-
0.28
0.33
0.38
0.3
0.33
0.38
0.44
-
0.28
0.31
0.37
0.38
0.43
0.49
0.57
0.32
0.36
0.41
0.48
0.51
0.57
0.65
0.76
0.46
0.51
0.59
0.68
0.61
0.68
0.78
0.91
0.61
0.68
0.78
0.91
0.81
0.91
1.04
1.21
0.76
0.85
0.98
1.14
0.9
1.02
1.16
1.35
1.01
1.14
1.3
1.52
1.21
1.37
1.56
1.82
Power output in kW
Rated voltage
Model
DHC-E
3.0
3/3.5-1
Trend
3.5
2.9
DHC-E
4.5
4/6-2
3.8
Trend
6.0
5.4
DHC-E
7.2
8/10-2
7.2
Trend
9.6
9.0
DHC-E
12/15-2
10.8
Trend &
12.0
Plus
14.4
Power output in kW
Rated voltage
Model
DHC-E
3.0
3/3.5-1
Trend
3.5
2.9
DHC-E
4.5
4/6-2
3.8
Trend
6.0
5.4
DHC-E
7.2
8/10-2
7.2
Trend &
Plus
9.6
9.0
DHC-E
12/15-2
10.8
Trend &
12.0
Plus
14.4

17.4 Application areas/conversion table

Here, data is shown for electrical resistivity and electrical conduc-
tivity.
Standard specifica-
Min.
Max.
Min.
resistivity
conductivity
resistivity
ρ ≥
ρ ≥
Ωcm
mS/m μS/cm
Ωcm
1100
91
910
970
17.4.1 Sizing the pipework
When calculating the size of the pipework, an water heater pressure
drop of 14.5 psi (0.1 MPa) is recommended.

17.5 Fault conditions

In the event of a fault, temperatures up to 176 °F (80 °C) at a pressure
of 145 psi (1.0 MPa) can occur briefly in the installation.
38 °C DHW output in l/min
Cold water inlet temperature
5 °C
10 °C
15 °C
20 °C
1.3
1.5
1.9
2.4
1.5
1.8
2.2
2.8
1.3
1.5
1.8
2.3
1.9
2.3
2.8
3.6
1.7
2.0
2.4
3.0
2.6
3.1
3.7
4.8
2.3
2.8
3.4
4.3
3.1
3.7
4.5
5.7
3.1
3.7
4.5
5.7
4.2
4.9
6.0
7.6
3.9
4.6
5.6
7.1
4.6
5.5
6.6
8.5
5.2
6.1
7.5
9.5
6.2
7.3
8.9
11.4
50 °C DHW output in l/min
Cold water inlet temperature
5 °C
10 °C
15 °C
20 °C
1.0
1.1
1.2
1.4
1.1
1.3
1.4
1.7
-
1.1
1.2
1.4
1.4
1.6
1.8
2.1
1.2
1.4
1.6
1.8
1.9
2.1
2.4
2.9
1.7
1.9
2.2
2.6
2.3
2.6
2.9
3.4
2.3
2.6
2.9
3.4
3.0
3.4
3.9
4.6
2.9
3.2
3.7
4.3
3.4
3.8
4.4
5.1
3.8
4.3
4.9
5.7
4.6
5.1
5.9
6.9
Max.
Min.
Max.
conductivity
resistivity
conductivity
ρ ≥
mS/m μS/cm
Ωcm
mS/m μS/cm
103
1031
895
112
www.stiebel-eltron-usa.com
1117

Publicité

Table des Matières
loading

Table des Matières