Télécharger Imprimer la page

Monacor SCA-400 Mode D'emploi page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
GB
Unfold page 3. Then you can always see the operating
elements and connections described.
1 Connections
1.1 Front panel (fig. 1)
1 Voltage control LED, lights if the operating voltage for the
camera has been adjusted optimally
2 On/off switch
3 Power indication
1.2 Rear panel (fig. 2)
4 Screw connections for a 24 V~ voltage supply via a sepa-
rate mains transformer (alternatively to the included plug-
in transformer)
5 AC voltage connection for the included plug-in transformer
(230 V~/24 V~)
6 Control for the operating voltage of the camera
7 BNC video output (1 Vpp/75 Ω) for the monitor
8 BNC jack for the camera (video input and operating volt-
age output for the camera)
9 Slide switch for the cable length compensation
2 Safety Notes
This appliance corresponds to the directive for electromagnet-
ic compatibility 89/336/EEC and the low voltage directive
73/23/EEC.
The plug-in transformer uses lethally high voltage (230 V~).
To prevent a shock hazard do not open the cabinet. Leave
servicing to authorized skilled personnel only. Furthermore,
any guarantee claim expires if the unit has been opened.