Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
3.

Safety Distances

The indicated safety distances apply to flammable
materials or materials with flammable parts with a
thermal resistance of R ≤ 7,2 m²K/W.
For particularly temperature-sensitive materials like
glass, larger distances may be necessary.
Within a radius of 120 cm in front, 60 cm on the right
and 25 cm on the left side of the stove, flammable,
combustible, or heat-sensitive materials (e.g. furni-
ture, wood or plastic panelling, curtains, etc.) are
not allowed to be located in the heat radiating area
of the fire box window (fig. 1).
Outside the radiation area of the fire box window, a
safety distance of 5 cm sideways and 7* cm behind
the stove is to comply to flammable materials (fig.
1). Above the stove, the safety distance of 65 cm to
flammable materials has to be complied with (fig. 2).
No flammable or temperature-sensitive materials
may be present within a radius of 20 cm around the
flue pipe connection (wall or room ceiling).
WARNING!
Flammable
flooring
materials
wood, laminate, carpeting,) must be
protected with a floorplate made of
non-combustible material (e.g., tiles,
safety glass, slate, or sheet steel).
The size of the floorplate must be larg-
er than the base of the stove by at least
50 cm in front and at least 30 cm at the
sides of the stove (fig. 3).
25
5
(e.g.,
fig. 1
* F or highly-insulated components with a thermal insulation resistance
of R ≤ 7,2 m²K/W, there should be a gap of 10 cm
60
60
fig. 2
16
fig. 3
50
50
147
floor-plate
Dimensions in cm
49