Stadium Mode - Villeroy & Boch ProDetect 2 Mode D'emploi

Masquer les pouces Voir aussi pour ProDetect 2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation

15.4.3 Stadium mode

High frequency of use is detected automatically by the system.
If 5 uses are detected one after the other, at an interval of less than 60 seconds in each case, the
controller switches automatically to stadium mode. In this mode the flushes are carried out at a
cycle time of 180 seconds, independent of the number of uses. If a flush volume of > 0.8 litres
is set, the flush volume is reduced to 0.8 litres.
If use is not detected during the 180 second flush interval, the system automatically switches
back to normal mode. A final flush is carried out with the set flush volume.
Activating and deactivating stadium mode
1.
Push both keys for 5 seconds.
The LED flashes once after 5 seconds.
2.
Release both keys.
Stadium mode activated = LED lights up for 2 seconds
Stadium mode deactivated = LED lights up twice
S. 65
P h
R
FF
FF
P h
R
f
y

Publicité

Table des Matières
loading

Table des Matières