Transport And Installation; Place Of Installation, Positioning And Fire-Prevention Safety - Cola FREE Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 TRANSPORT AND INSTALLATION

2.1 Packing, handling, shipment and transport
The stove complete with packing can be lifted using a lift truck, inserting the forks (of suitable length) in the special
spaces in the wooden pallet. Make sure the equipment used for lifting and transport can take the weight of the stove,
specified on the dataplate and in this manual.
Avoid taking the load in areas where it could be a danger if dropped.
Open the packing, remove the stove from the pallet and position it in the required place, making sure it complies
with that provided for.
Set the stove down on the floor carefully without bumping and position it in the required place. Make sure the floor
can take the weight of the stove, otherwise consult a specialised technician.
Disposal or recycling of the packing must be carried out by the end-user in compliance with the current local
regulations.

2.2 Place of installation, positioning and fire-prevention safety

The place of installation must be sufficiently ventilated to allow the removal of any combustion smoke leaks.
The unit is suitable for operation in domestic environments with min. temperature not below 0° C.
To prevent the risk of fire, the structures surrounding the stove must be protected from the heat.
Floors in wood or in any flammable material must be suitably protected at the base with steel or toughened glass
panels; the protection must cover the base and also a certain area in front of the stove.
Any wooden boards or beams above or crossed by the flue must be suitably protected in conformity with the
requirements of the specific current installation standards.
The minimum front distance for the protection of flammable objects is 1.5 m. The minimum safety distances from
flammable materials must comply with the following table:
Antiwind grille
Flue
Flue connection
Inspection door on
flue
Air inlet
min. 100 cm²
T union with
inspection cap
Floor protection base
38
A = 300 mm
B = 200 mm
C = 1500 mm
D = 200 mm
FREE

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Energy

Table des Matières