You go back to the configuration page of the recharge program.
Once modified the settings of WMarine10 these become operative only after the exiting from the configuration pages
pressing simultaneously for at least 2 seconds the buttons
Error and warnings codes
With the intervention of del WMarine10 internal protections, there are the below reported error codes.
The battery was connected with
inverted
electrical connections of the battery.
Overload protection occurred. The
load current exceeded the maximum
allowed limit for WMarine10 (Iload in
the "Table of electrical features") and
the device detached the load to
prevent internal damages. If there is
such a signalling, it is necessary to
check if the current absorbed by the
load is < than the allowed limit. After
1 minute WMarine10 tries to power
supply again the load. It exits from this
condition if the cause that generated
the overload has been eliminated.
When low battery symbol is flashing this indicates that there is the low battery protection - load has
been disconnected to preserve battery life. This protection intervenes when the battery voltage goes
under V
battery will be charged by the PV module at Velb voltage (settable).
Float Voltage
You can set
Float Voltage (Vflt at 25°C). When battery voltage is equal to charge voltage
(Veoc) for Tabs time, WRM15 enter in float state, where battery voltage is set to Vflt.
Float Voltage is temperature compensate (
Absorption time
You can set
Absorption time in hours (Tabs). When battery voltage is in Veoc livel for
Absorption time, the WMarine10 start float state, where battery voltage is set to Vflt.
Software version display page
It displays the software version in use on WMarine10.
This manual refers to software version 1.2.
polarities.
Check
threshold that can be set by the user (Tab.2). WMarine10 leaves this protection when the
LB
WMarine10
User manual
-24mV/°C at 12V and -48mV/°C at 24V
Tab.2 Setting pages
.
Table of Error code
the
Warnings
Tab.3 Table of error codes
7
You
have
this
error
temperature of WMarine10 exceeds 80°C
and deactivates the charge. You exit
automatically from this protection when the
internal
temperature
threshold of 50°C (note: the internal
temperature of the charge controller is not
displayed on the LCD). If you see often this
protection we advise to place the device in a
cooler place.
You have this error when the battery voltage
is < than 9.0V. In these conditions, the
charge is disabled.
EN
).
when
internal
goes
below
the