Installation Instructions - INDU+ TOMBOY DUO UNICO Mode D'emploi Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

The installation is the exclusive responsibility of specialists.
The user of this appliance is held to respect the legislation and the standards enforced in his
home country.
How to stick the gasket:
Fitting - installing:
 The dimensions are:
Cut size
Type
Width
IDP38TY
360
IDP58TY
560
 Ensure that there is a distance of 50 mm between the hob and the wall or sides.
 The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or device can be higher than the
hob.
 The piece of furniture or the support in which the hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 100 °C.
 The mural rods of edge must be heat-resisting.
 Do not install the hob to the top of a non- ventilated oven or a dishwasher.
 To ensure good air circulation of the electronic device, maintain a space of 20 mm under
the bottom of the hob casing.
 If a drawer is placed under the work, avoid putting flammable objects in this drawer
(for example: sprays) or non-heat-resistant objects.
 Materials which are often used to make worktops expand on contact with water. To protect
the cutout edge, apply a coat of varnish or special sealant. Particular care must be given
when applying the adhesive joint supplied with the hob to prevent any leakage into the
supporting furniture. This gasket guaranties a correct seal when used in conjunction with
smooth work top surfaces.
 The safety gap between the hob and the cooker hood placed above must respect the
indications of the hood manufacturer. Respect a distance of at least 760 mm if you do not
have further instructions.
 The connecting cable cannot be subjected to mechanical constraint (e.g. a drawer) after
construction.
Flush mounting
Depth
Width
Depth
490
386
526
490
586
526
Stick the gasket (2) two millimetres
from the external edge of the glass,
after removing the protection sheet (3).
Radius
Width
8
380
8
580
59
Glass size
Depth
Thickness
520
6
520
6