a.
Disconnect all power to the light before
performing any maintenance.
b.
Twist the lamp to unlock it and then pull
the defective lamp out of the socket.
c.
Install new lamp by aligning lamp pins
with socket. Push lamp down and twist to lock into posi-
tion.
2.
Strobe Assembly Replacement (see figure 7).
High Voltages are present inside the lightbar.
Wait at least ten (10) minutes, after shutting
off power, before servicing this unit. Failure
to do so may result in property damage,
serious injury, or death to you or others.
a.
Disconnect ALL power to the unit before
any maintenance is performed.
b.
Remove and retain the 4 mounting screws
that secure the bracket to the EMS Escape extrusion.
c.
Disconnect the wire connector from the
defective strobe assembly.
d.
Remove and retain the (4) #6 x 3/8"
thread forming screws which secure the strobe assembly to
the mounting bracket.
e.
Remove and discard the defective strobe
assembly.
f.
Install the new strobe assembly by
performing the previous steps in reverse order.
3.
GHSCENE Halogen Lamp Replacement (see
figure 8).
A serious injury may result if lamp is touched
when hot. Always allow lamp to cool before
removing. Halogen lamps are pressurized
and if broken can result in flying glass.
Always wear gloves and eye protection when
handling the lamps.
CAUTION
Service life of lamp will be shortened if glass
portion is touched. If glass has been handled, clean
carefully with a grease solvent.
a.
Disconnect all power to the light before
performing any maintenance.
b.
Remove and retain the two screws and
clips that secure the halogen lamp. Remove the halogen
lamp by pulling it straight away.
This device is designed to use a 20-watt
(maximum) halogen lamp. Use of higher
wattage lamps can result in damage to the
lens, property damage, or serious injury to
you or others. Always use a 20-watt halogen
lamp.
WARNING
WARNING
WARNING
c.
Install the new halogen lamp in the rear
housing using the previously removed screws and clips.
d.
Reconnect all power connections to the
power source and test for proper operation.
4.
MODLED LED Module Replacement (see
figure 9.)
a.
Disconnect ALL power to the unit before
any maintenance is performed.
b.
Remove and retain the 4 mounting screws
that secure the bracket to the EMS Escape extrusion.
c.
Disconnect the wiring connector from the
MODLED led module assembly.
d.
Remove the three #8x1/2" screws that
hold the module secure to the bracket.
e.
Remove the connector from the defective
module.
f.
Insert the connector into the replacement
module.
g.
Install the new MODLED led module by
performing the previous steps in reverse order.
h.
Reconnect all power connections to the
power source and test for proper operation.
5.
EMSHAL Halogen Lamp Replacement (see
figure 10).
A serious injury may result if lamp is touched
when hot. Always allow lamp to cool before
removing. Halogen lamps are pressurized
and if broken can result in flying glass.
Always wear gloves and eye protection when
handling the lamps.
a.
Disconnect ALL power to the unit before
any maintenance is performed.
b.
Remove and retain the 2 keps nuts that
secure the halogen reflector.
c.
Remove the spacer that secures the
halogen lamp to the reflector assembly
d.
Remove the defective lamp by carefully
pulling it out of the bracket.
e.
Disconnect the halogen wire from the
power cable. While holding on to the power cable, connect
the new halogen lamp wire to the power cable.
Access to the halogen bulb/power cable connection
may not be accessible and may require removal of
the mounting bracket.
-5-