Step 2
The device should only be set up in dry rooms. It must be placed horizontally
and must not be hung up. The location must be well ventilated. The charger
should be placed as close as possible to the battery, but
box.
The box for the battery must have a ventilation hole facing towards the
outside.
The space provided for the device must
specified here, since a minimum clear distance of 100 mm must be provided all
the way around it:
Length: 475 mm
Width: 390 mm
Height: 215 mm
The separate box for the device must be provided with ventilation holes at the
top and sides, with a total area of 5000 mm².
Step 3
Attach the device securely with the four fastening screws supplied.

Connection

Disconnect the power cables from the
connecting or disconnecting any cables!
Only use cables with the specified cross-sections!
Prepare the cables for connecting the 6-pole plug:
o 12 V consumer 1
o 12 V consumer 2
o 12 V consumer 3
o Heating / immed.light
o Water pump
o Refrigerator
Trautmann GmbH & Co. KG
Lerchenfeldstr. 9
Internet: http://www.calira.de
Operating instructions
battery and from the mains before
at least
at least
at least
at least
at least
87600 Kaufbeuren
always in a separate
not
be smaller than the dimensions
1.50 mm²
1.50 mm²
2.50 mm²
1.50 mm²
1.50 mm²
2.50 mm²
-Apparatebau
CALIRA
Tel.08341/9764-0 Fax 08341/67806
Email: info@calira.de