HALFEN HLX
Inspections
According to the inspection criteria regular inspections are
required; after exceptional incidents additional inspections
are required. All inspections have to be documented in an

inspection record.

Regular inspections / inspection before application
The contractor or operator must ensure that the HALFEN
HLX Lift-Box system is inspected at regular intervals.
Before each use, it must be ensured that the last inspection
and confi rmation of usability was within the last 12
months.
Frequent use or environmental eff ects may require shorter
periods between inspections. The inspections must only be
executed by qualifi ed persons and have to be recorded in
the inspection record.
Additional inspections
After unusual incidents which may infl uence the load
capacity of the HALFEN HLX Lift-Box or after maintenance
work, the contractor or operator has to ensure that an
additional inspection is done by a suitably qualifi ed
person and documented in the inspection record.
Inspection criteria
• Good, undamaged condition of the HALFEN HLX Lift-
Box components — signs of corrosion, broken strands
in the cable and visible deformations are not allowed.
• Perfect condition of the concrete slab — visible cracks,
spalling in the concrete and signs of corrosion are not
allowed.
Year of production:
Date of purchase:
Date
Reason for inspection
(maintenance work or
regular periodical check)
6
• Proper condition of the marking – the anchorage point is
not to be used if the marking is not legible or missing.
• Cable loops must be checked for the following defects:
Do not use HLX Lift Box if the following number of broken
wires are visible:
Wire breaks
Cable type
strand
cable
Inspection record
Inspection
Detected defi ciencies and
required maintenance work
Assembly Instructions
kinking
breakage in a loop
loosening of the exterior wires in the length of
the cable
compressive deformation
crushing in the load area of the load loop with
more than 4 wire breaks
in strand-cables and more than 10 breaks in
wire-laid cables
signs of corrosion
damage or exaggerated wear in the cable or cable
ferrule
large number of broken wires
Slippage between the cable loop and the ferrule
Visible wire breaks over a cable length of
3d
4
Date of fi rst use:
Identifi cation no.
Name / signature
of inspector
© 2020 · INST_HLX 04/20 · www.halfen.com
6d
10d
6
16
Date of next
inspection due: