Scope of application

Elevator lifting device acc. to ETA-17/0488
The HALFEN HLX Lift-Box is installed in the underside
of concrete slabs (e.g. in lift shafts). It serves as an
anchorage point for temporary suspension of objects
used during installation or maintenance.
Requirements for installation and allowable load
capacities can be found in the tables included with
these installation instructions.
Type variants
The HLX Lift-Box is available in 2 types with 3 load steps.
The HLX Loop with wire loop or the HLX Link with chain
link.
Both systems are robust and designed for attaching hooks,
and can be folded back into the box after use.
The installation sequence for both variants is the same.
Installation
1
2
3
4
2
The HALFEN HLX Lift-Box must only be installed by trained
and qualifi ed personnel.
HLX Lift-Box Loop
(with wire loop)
The use of incomplete anchors is not allowed. Missing components
may only be replaced by the manufacturer. The use of non-system
components can result in reduced safety of the unit; may also result
in anchor failure causing suspended construction elements to fall. This will
endanger people in the vicinity and may result in serious injury or death.
The anchor system must be checked for integrity before each application.
Any change, adapting or welding to the anchor is not allowed. This may cause
the attached load to fall, resulting in injury or death. The HALFEN HLX Lift-Box
may only be used in an unmodifi ed and original state.
The HALFEN HLX Lift-Box is installed in the underside of concrete slabs
(e.g. in lift shafts).
The condition of the HALFEN HLX Lift-Box components and the concrete slab
must be visually inspected before each use. The system must be evaluated by
a qualifi ed person if there is doubt about its integrity.
The correct position of the anchorage point is determined by (notches)
1
markings in the lid.
The HALFEN HLX Lift-Box can be attached with the included nails or
2
fi rmly glued (e.g. to steel formwork). The minimum spacings (see table 3)
must be observed. For reinforcement installation, please refer to the
section "Element requirements".
The concrete must be poured and compacted carefully around the
3
HALFEN HLX Lift-Box. Avoid direct contact between the vibrator and the
HALFEN HLX Lift-Box components. Remove the formwork carefully to
avoid any damage.
4
Remove the lid and nails.
Note: The load bearing loops must not come into contact with
chemicals or other aggressive substances.
Assembly Instructions
Attention: The HALFEN HLX Lift-Box is not
intended for use as a personal fall protection
unit according to EN 795.
HLX Lift-Box Link
(with chain link)
© 2020 · INST_HLX 04/20 · www.halfen.com