Stainless steel hose clamp.
T of 135° with outlet.
Elbow of 45°.
Wooden ground.
Non flammable floor protection.
Stainless steel flexible tube.
Rigid flexible pole adapter.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 4 m in length, the next larger
size will be used.
4.26. Installing a fitted stove in a brickwork chimney can be done using flexible piping in its entirety, as indicated in
drawing 7. We must take special care when sealing the chimney and gas venting to avoid gas blowing back
during storms.
Stainless steel hose clamp.
T of 135° with outlet.
Elbow of 45°.
Wooden ground.
Non flammable floor protection.
Stainless steel flexible tube.
Rigid flexible pole adapter.
Anti blow-back seal.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 4 m in length, the next larger
size will be used.
When installing a flexible tube for gas outlet, be careful that this is not in contact or close to the circuit board
or combustible material.
The room sensor (
You will know the stove recognize that because the room temperature it will be shown in the control panel. If you
connect a thermostat or contact instead of displaying the room temperature it will be shown ( · ) indicating this that
there is something connected in the communication port.
IF YOU HAVE ANY DOUBT ABOUT THE CONNECTION, THE INSTALLATION PRACTICABILITY OR THE USE OF
SUCH DEVICES, CONTACT YOUR DISTRIBUTOR WHO WILL INFORM YOU.
POWER WIRING AND ROOM THERMOSTAT.
) and the power wire are connected at the rear of the stove as shown in the diagram.