Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
become noisier.
• FIXING TO THE WALL
Drill the holes A respecting the distances indicated
(Fig.2). Fix the appliance to the wall and align it in
horizontal position to the wall units. When the appliance
has been adjusted, definitely fix the hood using the
screws A (Fig.4). For the various installations use
screws and screw anchors suited to the type of wall
(e.g. reinforced concrete, plasterboard, etc.). If the
screws and screw anchors are provided with the
product, check that they are suitable for the type of wall
on which the hood is to be fixed.
• FIXING THE DECORATIVE TELESCOPIC FLUE -
EXTRACTOR VERSION
Arrange the electrical power supply within the dimen-
sions of the decorative flue. If your appliance must be
installed as an extractor version, make sure an air ex-
haust hole has been prepared. Adjust the width of the
support bracket of the upper flue (Fig.3).
Then fix it to the ceiling using the screws A (Fig.3) in
such a way that it is in line with your hood and respecting
the distance from the ceiling indicated in Fig.2. Connect
the flange C to the air exhaust hole using a connection
pipe (Fig.4).Insert the upper flue into the lower flue. Fix
the lower flue to the hood using the screws B provided
(Fig.4), extract the upper flue up to the bracket and fix it
with the screws B (Fig.3). To transform the hood from a
ducting version into a filtering version, ask your dealer
for the charcoal filters and follow the installation instruc-
tions.
• FILTERING VERSION
Install the hood and the two flues as described in the
paragraph for installation of the hood in ducting version.
To assemble the filtering flue refer to the instructions
contained in the kit.
The charcoal filters are already fitted to the appliance
(Fig.7).

USE AND MAINTENANCE

• We recommend that the cooker hood is switched on
before any food is cooked. We also recommend that
the appliance is left running for 15 minutes after the
food is cooked, in order to thoroughly eliminate all
contaminated air.
The effective performance of the cooker hood depends
on constant maintenance; the anti-grease filter and the
active carbon filter both require special attention.
• The anti-grease filter is used to trap any grease
particles suspended in the air, therefore is subject to
saturation (the time it takes for the filter to become
saturated depends on the way in which the appliance
is used).
- To prevent potential fire hazards, the anti-grease
filters should be washed a minimum of every 2 months
(it is possible to use the dishwasher for this task).
- After a few washes, the colour of the filters may
change. This does not mean they have to be replaced.
If the replacement and washing instructions are not fol-
lowed, the anti-grease filters may present a fire hazard.
• The active carbon filters are used to purify the air
which is released back into the room. The filters are not
washable or re-usable and must be replaced at least
once every four months. The active carbon filter
saturation level depends on the frequency with which
the appliance is used, the type of cooking performed
and the regularity with which the anti-grease filters are
cleaned.
• Clean the cooker hood frequently, both inside and
outside, using a cloth which has been dampened with
denatured alcohol or neutral, non-abrasive liquid
detergents.
• The light on the cooker hood is designed for use during
cooking and not for general room illumination. Extended
use of the light reduces the average duration of the bulb.
COMMANDS: (Fig.9)
Push-button A = on/off lights switch
Push-button B = on/off cooker hood switch. The ap-
pliance switches on at speed level 1, If the cooker hood
is on depress the push-button for 2 sec. to switch off
the cooker hood. If the cooker hood is at speed level 1
it will not be necessary to depress the push-button to
switch the cooker hood off. Decreases the motor speed.
Display C = indicates the motor speed level selected
and activates the timer.
Push-button D = switches on the cooker hood. In-
creases the motor speed. Touching the key at 3rd
speed, the intensive function runs for 10', then the
appliance go back to work at the original speed. During
this function the display blinks.
Key E = The Timer times the functions on activation for
15 minutes, after which they are switched off. The Timer
is deactivated by re-pressing Key E. When the Timer is
activated the decimal point must flash on the display.
The "clean air" function is activated by pressing key E
for 2 seconds when the appliance is switched off. This
switches the motor on for 10 minutes every hour at the
first speed. During functioning a rotary movement of
the peripheral segments must be visualised on the
display. When this time has passed the motor switches
off and the fixed letter "C" must be visualised on the
display until the motor re-starts after 50 minutes for
another 10 minutes and so on. Press any key apart from
the light keys to return to normal functioning. Press key
E to deactivate the function.
• Active carbon/grease filter saturation:
- When display item C flashes, at a speed where it
alternates with the letter F (e.g. 1 and F), the grease
filters must be washed.
- When display item C flashes, at a speed where it
alternates with the letter A (e.g. 1 and A), the carbon
filters must be replaced.
After the clean filter has been positioned correctly, the
electronic memory must be reset by pressing button A
for approximately 5 seconds, until the indication F or
A shown on the display C stops flashing.
• COMMANDS: (Fig.8) LUMINOUS the key symbols
are explained below:
A = LIGHT
- 19 -