Technical Data And Drawings; Technical Data Table; Transformation; Instructions For Installation - Lotus cooker FT T-64ET Série Instructions Pour L'installation Et L'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The data plate is attached to the back panel (see drawing electrical connection point) and contains all the information
necessary for connection.
MODELS
DIMENSIONS cm POWER SUPPLY
FT*T-64ET**
40x60x29h
60x60x29h
FT*T-66ET**
FT*T-68ET**
80x60x29h
FT*T-610ET**
100x60x29h
FTCT-64ET
40x60x29h
FTCT-66ET
60x60x29h
MODELS
DIMENSIONS cm POWER SUPPLY
FT*T-64ET**
40x60x29h
FT*T-66ET**
60x60x29h
FT*T-68ET**
80x60x29h
FTCT-64ET
40x60x29h
FTCT-66ET
60x60x29h
FT*T-66ET**
60x60x29h
FTCT-64ET
40x60x29h
60x60x29h
FTCT-66ET
*L = Smooth hotplate – R = Corrugated hotplate - L/R = ½ Smooth +1/2 Corrugated
**S= Chromium-plated hotplate
The data plate is on the side of the appliance (see figure A) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc., these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
Attention! This appliance has been produced for use as part of a battery. If used singly, it will be necessary to keep it at
least 10cm away from the adjacent walls.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, norms in force.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
GB

TECHNICAL DATA AND DRAWINGS

TECHNICAL DATA TABLE

400V~3N 50/60 Hz
400V~3N 50/60 Hz
400V~3N 50/60 Hz
400V~3N 50/60 Hz
400V~3N 50/60 Hz
400V~3N 50/60 Hz

TRANSFORMATION

230V~3 50/60 Hz
230V~3 50/60 Hz
230V~3 50/60 Hz
230V~3 50/60 Hz
230V~3 50/60 Hz
230V~ 50/60 Hz
230V~ 50/60 Hz
230V~ 50/60 Hz

INSTRUCTIONS FOR INSTALLATION

INSTALLATION

LAWS, TECHNICAL RULES AND NORMS

IE
MAXIMUM
MAXIMUM
POWER (kW)
ABSORPTION (A)
4,5
6,75
9
11,25
2,2
3,3
MAXIMUM
MAXIMUM
POWER (kW)
ABSORPTION (A)
4,5
6,75
9
2,2
3,3
6,75
2,2
3,3
22
POWER SUPPLY
CABLE (Silicon)
6,52
5 x 1,5 mm²
9,78
5 x 1,5 mm²
13,04
5 x 1,5 mm²
16,3
5 x 2,5 mm²
3,19
5 x 1 mm²
4,78
5 x 1 mm²
POWER SUPPLY
CABLE
(Silicone)
11,3
4 x 1,5 mm²
16,94
4 x 2,5 mm²
22,59
4 x 2,5 mm²
5,52
4 x 1 mm²
8,28
4 x 1 mm²
29,35
3 x 4 mm²
9,56
3 x 1,5 mm²
14,34
3 x 1,5 mm²