Insert the unit with the seal into the sleeve pushing it all the
way to the rear, making sure the seals are against the rear
grille. The seals are necessary to reduce recirculation of hot
air into the intakes which will reduce system performance.
An alternative is to purchase a 3/4" diamond cut aluminum
grille and cut it to fit inside the sleeve. Secure it with screws.
Attach the dual intake grill directly to the back of the unit.
Slide the entire unit into the sleeve and seal with the stuffing
seal supplied with the kit.

Trim Kit Installation Instructions

1. Install the 1" x 1" x 84" long stuffer seal between the
wall sleeve and the unit. A flat-bladed screwdriver or
putty knife is needed.
2. Assemble the trim frame by inserting the top and
bottom pieces into the side pieces and snapping them
into place.
3. Pull the cord through the trim frame and slide the trim
over the unit until it is flush with the wall.
Energy saving suggestion: In order to reach maximum
energy savings and comfortability, it is necessary to
use an appropriately sized cover to provide additional
insulation and air sealing during the off season.
AIR CONDITIONER USAGE
Electronic Control Panel & Remote Control
Note: This display shows the room temperature in Fan
Mode except when setting the Set temperature or Timer.
For Cooling Model
9
8
For Heating Model
9
8
Air Conditioner Controls
Fig. 7
Normal Operating Sounds
• You may hear a pinging noise caused by water hitting
the condenser on rainy days, or when the humidity is
high. This design feature helps remove moisture and
improve efficiency.
• You may hear the thermostat click when the compressor
cycles on and off.
• Water will collect in the base pan during rain or days of
high humidity. The water may overflow and drip from
the outside part of the unit.
• The fan may run even when the compressor is not on.
Through The Wall
Air Conditioner
1
2
3
7
6
5
4
1
2
3
7
6
5
4
1. Digital Display: Without the timer setting, the operation mode
is Cooling, Dry, Fan and Auto, and the set temperature will be
displayed. Time will be displayed under the timer setting.
and
Buttons: Use these buttons on the control panel
2.
and remote to increase or decrease the Set Temperature or
Timer. Temperature range: 61 ~ 88 or 16 ~ 31.
3. Power Button: Turn the air conditioner on and off.
4. Mode Button: Press the mode button to cycle through the
various modes: Cool, Dry, Fan and Auto, or Heat.
Cool Mode: The cooling function allows the air conditioner
to cool the room and at the same time reduces air humidity.
Press the MODE button to activate the cooling function.
To optimize the function of the air conditioner, adjust the
temperature and the speed by pressing the button indicated.
Dry Mode: This function reduces the humidity of the air to
make the room more comfortable. Press the MODE button
to set the DRY mode. An automatic function of alternating
cooling cycles and air fan is activated.
Fan Mode: The conditioner works in only ventilation. Press
the MODE button to set the FAN mode. With pressing the
FAN SPEED button the speed changes in the following
sequence: Hi, Med and Lo in FAN mode. The remote
control also stores the speed that was set in the previous
mode of operation.
Auto Mode: In AUTO mode, the unit automatically chooses
the fan speed and the mode of operation (COOL,DRY or
FAN). In this mode the fan speed and the temperature
are set automatically according to the room temperature
(tested by the temperature sensor which is incorporated in
the indoor unit.)
Heat Mode: The heating function allows the air conditioner
to heat the room. Press the MODE button to activate
the heating function. To optimize the function of the air
conditioner, adjust the temperature and the speed by
pressing the button indicated.
5. Timer Button: Use these buttons on the control panel
and remote to set the Timer.
Timer Off: The timed stop is programmed by pressing the
TIMER button. Set the rest time by pressing the
buttons until the rest time is displayed to your preference
then press the TIMER button again.
Timer On: When the unit is off, press the TIMER button once
to set the temperature by pressing the
Press the TIMER button twice to set the rest time by pressing
the
or
buttons. Press the TIMER button three times
to confirm the setting, then the rest time will automatically
switch on and be read on the display of the machine.
Note: It can be set to automatically turn off or on in 0.5-
24 hours. The
buttons will increase or decrease the
timer. The Timer can be set in 0.5 hours increment below
10 hours and 1 hour increments for 10 hours or above.
The SET light will turn on while setting. To cancel the set
function, press the TIMER button again.
6. Eco Button: When the unit is in ECO mode, the light will
turn on. In ECO mode, the unit will turn-off once the room
is cooled to the user set temperature. The fan will also
be off at this point. The unit will restart when the room
temperature rises above the user set temperature. Before
the compressor starts, the fan motor will start and stop
repeatedly for cooling comfort and energy efficiency.
4
User's Manual
or
or
buttons.