In Case Of Problems - babymoov Babyphone High Care Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Problem
• No transmission from the transmitter.
• Transmits without interruption.
• Out-of-range alarm activated without
interruption.
• The out-of-range alarm is activated
sometimes without reason.
• The out-of-range alarm is never
activated.
• The temperature alarm is activated
without interruption.
• The battery low warning is displayed
without interruption.
• The battery life of the receiver is
too short.
• The battery life of the transmitter is
too short.
• A lot of static and interference.
• Too short communication range.
20

IN CASE OF PROBLEMS

Possible cause
• The microphone sensitivity is set too low.
• The batteries have run out or the AC
adapter is not properly connected.
• The microphone sensitivity is set too high.
• The channel or digital code setting is
not the same on the transmitter and
the receiver.
• The transmitter batteries have run out.
• The out-of-range alarm setting on the
transmitter is on Off but the setting on the
receiver is on On.
• Interferences with other appliances
operating on the same channel.
• The out-of-range setting on the
transmitter and the receiver is on Off.
• The out-of-range alarm setting in the
transmitter is on On but the setting in
the receiver is on Off.
• The
maximum
temperature limits are too close to the
current reading.
• The battery has run out.
• No battery inside the receiver.
• The battery is damaged.
• The night light is on permanently.
• The vibration alarm is on.
• The transmitter is located close to other
electrical apparatus.
• A large number of steel structures
between the transmitter and the receiver.
• The power output on the transmitter is set
to Lo.
• The transmitter batteries have run out.
• Transmitter's range check is set to On.
BABYPHONE HIGH CARE • Instruction Manual
• Increase the microphone sensitivity using
the selection button (2).
• Install new batteries or check the
connection.
• Decrease the microphone sensitivity using
the selection button (2).
• Set the same channel and same digital
code on the transmitter and the receiver.
• Replace them with new batteries or use
the AC adapter.
• Change the setting of the out-of-range
alarm on the transmitter to On.
• Change to another channel.
• Change both settings to On.
• Change the setting on the receiver to On.
and
minimum
• Adjust the maximum and minimum
temperature limits to obtain a difference
of 5 °C relative to the current reading.
• Recharge the battery using the (receiver)
charger base. Replace with new batteries
or use the AC adapter for the transmitter.
• Replace the battery in the battery
compartment.
• Replace with a new battery.
• Turn off the night light or set to VOX
function.
• Turn off the vibration alarm.
• Remove the electrical appliances or move
the transmitter away from the source of
interference or change the channel.
• Reposition the transmitter and the
receiver.
• Change the power output setting to Hi.
• Replace the batteries or use the AC
adapter.
• Set range check function to off.
Solution