• The inscrip on shall be indelible, inscribed on both sides of the warning sign and
have a height of at least 25mm.
• Ensure that all mains operated, ancillary equipment connected to the electric
animal fence circuit provides a degree of isola on between the fence circuit and
the supply mains equivalent to that provided by the energizer.
• Protec on from the weather shall be provided for the ancillary equipment
unless this equipment is cer fi ed by the manufacturer as being suitable for use
outdoors, and is of a type with a minimum degree of protec on IPX4.
The author thanks the Interna onal Electrotechnical Commission (IEC) for permission to reproduce
Informa on from its Interna onal Publica on 60335-2-76 ed.2.2 (2013). Annex BB-1. All such extracts
are copyright of IEC, Geneva, Switzerland. All rights reserved. Further informa on on the IEC is available
from www.iec.ch. IEC has no responsibility for the placement and context in which the extracts and
contents are reproduced by the author, nor is IEC in any way responsible for the other content or
accuracy therein.
WARNING: Risk of Electric Shock. Do not connect the energizer
simultaneously to a fence and to any other device such as a ca le trainer
or a poultry trainer. Otherwise, lightning striking your fence will be
conducted to all other devices.
SERVICE OF DOUBLE-INSULATED APPLIANCES
In a double-insulated controller, two systems of insula on are provided
instead of grounding. No equipment grounding means is provided in
the supply cord of a double-insulated controller, nor should a means for
equipment grounding be added to the controller. Servicing a double-insulated
controller requires extreme care and knowledge of the system, and should
be done only by qualifi ed service personnel. Replacement parts of a double
insulated controller must be iden cal to the parts they replace A double
insulated controller is marked with the words "DOUBLE INSULATION" or
"DOUBLE INSULATED". The symbol for double insula on
marked on the appliance.
To reduce the risk of electric shock, this fence controller has a polarized plug
(one blade that is wider than the other). This plug will fit in a polarized outlet
only one way. If the plug does not fit fully in the outlet, reverse the plug. If it
still does not fit, contact a qualified electrician to install the proper outlet. Do
not change the plug in any way. Save these instruc ons.
6
Gallagher 3E4412 Value Mains Energizer NA User Manual