• Connec ng leads and electric animal fence wires shall not cross above overhead
power or communica on lines.
• Crossings with overhead power lines shall be avoided wherever possible. If such
a crossing cannot be avoided it shall be made underneath the power line and as
nearly as possible at right angles to it.
• If connec ng leads and electric animal fence wires are installed near an
overhead power line, the clearances shall not be less than those shown in the
table following.
Minimum clearances from power lines for electric animal fences
Power line Voltage V
Less than or equal to 1 000
Greater than 1 000 and less than or equal to 33 000
Greater than 33 000
• If connec ng leads and electric animal fence wires are installed near an
overhead power line, their height above the ground shall not exceed 3 m
This height applies either side of the orthogonal projec on of the outermost
conductors of the power line on the ground surface, for a distance of:
2 m for power lines opera ng at a nominal voltage not exceeding 1 000 V;
15 m for power lines opera ng at a nominal voltage exceeding 1 000 V.
• Where an electric animal fence crosses a public pathway, a non-electrifi ed gate
shall be incorporated in the electric animal fence at that point or a crossing by
means of s les shall be provided. At any such crossing, the adjacent electrifi ed
wires shall carry warning signs.
• Any part of an electric animal fence that is installed along a public road or
pathway shall be iden fi ed by electric fence warning signs (G6020) at regular
intervals that are securely fastened to the fence posts or fi rmly clamped to the
fence wires.
• The size of the warning sign shall be at least 100mm x 200mm.
• The background colour of both sides of the warning sign shall
be yellow.
The inscrip on on the sign shall be black and shall be either:
the substance of "CAUTION: Electric Fence" or,
the symbol shown:
Clearance m