Dentsply Sirona Celtra Ceram Mode D'emploi page 17

Masquer les pouces Voir aussi pour Celtra Ceram:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

General firing recommendations –
Cut-back and Layering Technique
Celtra Press Framework
PowerFire: Framework only
Start
Drying
Closing
Temp
min
min
0:00
1:00
400
First firing: Dentin & Enamel
Start
Drying
Closing
Temp
min
min
2:00
2:00
400
Second firing: Dentin & Enamel
Start
Drying
Closing
Temp
min
min
2:00
2:00
400
Glaze Firing
Start
Drying
Closing
Temp
min
min
2:00
2:00
400
Add-on (with and after glaze firing)
Start
Drying
Closing
Temp
min
min
2:00
2:00
400
Pre-
Heating
heating
Rate
°C
min
°C/min
1:00
55
Pre-
Heating
heating
Rate
°C
min
°C/min
2:00
55
Pre-
Heating
heating
Rate
°C
min
°C/min
2:00
55
Pre-
Heating
heating
Rate
°C
min
°C/min
2:00
55
Pre-
Heating
heating
Rate
°C
min
°C/min
2:00
55
Final
Vacuum
Vacuum
Temp
Start
°C
°C
760
0
Final
Vacuum
Vacuum
Temp
Start
°C
°C
770
400
Final
Vacuum
Vacuum
Temp
Start
°C
°C
760
400
Final
Vacuum
Vacuum
Temp
Start
°C
°C
750
0
Final
Vacuum
Vacuum
Temp
Start
°C
°C
750
400
12
Vacuum
Hold
Stop
Hold Time
Time
°C
min
0
0:00
2:00
Vacuum
Hold
Stop
Hold Time
Time
°C
min
770
1:00
Vacuum
Hold
Stop
Hold Time
Time
°C
min
760
1:00
Vacuum
Hold
Stop
Hold Time
Time
°C
min
0
0
2:00
Vacuum
Hold
Stop
Hold Time
Time
°C
min
750
1:00
Cool
min
min
0:00
Cool
min
min
1:00
5:00
Cool
min
min
1:00
5:00
Cool
min
min
5:00
Cool
min
min
1:00
5:00