7. IMPORTANT INFORMATION FOR INITIAL OPERATION

Check the product for transport any damage. Notify the carrier if you find any transport damage.
Position the compressor as close to the working area as possible to avoid long air hoses and
extension cords.
Intake air must be dry and clean.
After filling the air tank the compressor engine must cool down for 2-5 minutes to avoid over-
heating.

8. OPERATION INSTRUCTIONS

Quick coupling (1)
Connect:
Put the plug of your hose directly into the coupling untill you hear a clicking sound.
Disconnect:
Pull back the sleeve of the quick coupling and pull out the plug.
Use the on/off switch (2) to operate the compressor. The maximum continous operation is „S3 15%"
(1.5 min on and then 8.5 min off for cooldown). After the engine is switched off, the remaining air
from the hose will vent with an audible hissing noise. This is normal and no sign of damage.
Troubleshooting:
Compressor engine does not work
Cause:
No power present.
Solution: Check cables, plugs, fuses and outlets.
Cause:
Power level too low.
Solution: Avoid using long extension cords. If you have to use extension cords, make sure they are
sufficently thick (at least 2.5 mm
Cause:
Ambient temperature too low.
Solution: Do not operate below 5 °C.
Cause:
Engine overheating.
Solution: Let the engine cool down. Do not operate above 40°C ambient temperature.
Compressor engine working, but no pressure
Cause:
Seals leaky.
Solution: Check seals and let a certified technician replace them.
ERBA GmbH
A-1230 Wien
Talpagasse 6