OPERATING INSTRUCTIONS
Empty the spray-gun of any residual paint into a separate
spills-dish.
Open the main valve for compressed air (item 8 illustration 1).
Open the lid.
Dismantle the spray gun and clean all parts using the brush
(item 2 illustration 1).
Press the pedal (item 9 illustration 1) to activate the pump that
feeds the brush with re-circulating solvent.
Rinse off any remaining dirt from the spray gun with a jet of
clean solvent as a fi nal step in the cleaning procedure.
As long as the valve (item 10 illustration 1) is turned on, a
jet of clean solvent will be sprayed from the nozzle (item 11
illustration 1) under the lid.
Finally, it is possible to blow out the spray-gun. Connect the
spray-gun to the air line on the left side of the machine (item 5
illustration 1), and blow out the spray-gun through the funnel
under the lid. By using this funnel, you prevent the fumes from
spreading within the premises.
Finally, all of the spray-gun's channels can be blown out with
the air-gun on the right side of the unit (item 6 illustration 1),
which can also be used to dry the spray-gun.
Close the lid after cleaning.

SERVICE

Weekly:
– Clean the washing compartment´s working platform (per-
forated pressing) and the bottom of the washing compart-
ment.
When changing drums:
– Check and if necessary clean the strainer on the suction
hose for circulating solvent.
230842 rev1 2017-02-04

SAFETY INFORMATION

Hazards may arise from improper use of the X-SERIES 11M.
Hazards may also arise from improper choice/handling of
drums or solvent. In order to maintain the high safety standard
of the unit, it is important that these instructions are followed.
– Do not operate the unit until you have read and fully under-
stood this entire User's Manual.
– The unit should be isntalled as described in the instructions.
– The unit should be used as described in the instructions.
– The unit should be maintained as described in the instruc-
tions.
– Only original spare parts may be used.
– This User's Manual must be available and in legible condi-
tion in close proximity to the unit. Every user shall know
where to fi nd the User's Manual.
– Operating instructions should be formulated on the basis of
this Users Manual, and translated into the language spoken
by the employees.
– Do not modify or in any way alter the unit.
– Do not operate the unit unless it is properly vented. Do not
operate the unit if the extraction of vapors is insuffi cient.
– Avoid contact with liquid and vapor. Refer to the solvents'
MSDS (Material Safety Data Sheet).
– Wear chemical goggles or similar, to protect your eyes.
Wear chemical-resistant gloves to prevent skin-contact.
Wear chemical-resistant clothing to protect against spills or
splash.
– Personnel suffering from respiratory problems or allergies to
solvents used, must not operate the machine.
– Clean up spills immediately. Solvent vapours are heavier
than air and can spread a long way. They may also collect
in pits or other low areas.
– Do not smoke, eat or drink while close to the unit.
– A fi re extinguisher must always be kept nearby when work-
ing with fl ammable solvents. Do not use water.
Spray guns or any other paint equipment items cleaned
in the unit must be suitable for cleaning in a Zone 1 area
(ref. Category 2 according to EN 13463-1/2001). If unsure,
please contact the spray gun manufacturer.
– The unit must be properly grounded using the attached
grounding cable. If plastic drums are used, the openings
should be wiped off with a damp cloth, to avoid static
electricity, before inserting or removing any hoses or other
equipment.