Installation Instructions Viewguard DUAL / AM FAI
6.
Start-up
6.1
Close housing
See Fig. 1 in reverse order. Ensure that the housing is closed correctly and locked into
position. Do not insert the seal to lock the housing until installation is completed
6.2
Apply operating voltage
After applying the operating voltage, the detector automatically performs an initialisation.
Both LEDs flash (see 7.).
Do not enter the Anti-Mask range during initialisation
60 seconds the detector is ready for operation. After this period, do not change anything in
the close vicinity (up to 50 cm) that may influence the reflected light.
6.3
Walk test
Carry out a walk test for each detector in all cases.
Check the surveillance area of the detector.
7.
LED indication
1
LED yellow: see Fig. 2-
Operating Mode
2
LED red: see Fig. 2-
Start-up
on
Walk test
flashing
blanked
After disarming
Normal operation
8.

Technical specification

Operating voltage Vnom
Operating voltge range
Current consumption at Vnom=12 V DC
Range (programmable):
PIR sensor
PIR sensitivity (programmable):
Anti-Mask function
(only AM detectors)
Frequency microwave:
-
033440.01 / 033441.01
-
033450.01 / 033451.01
Transmission power:
-
033440.01 / 033441.01
-
033450.01 / 033451.01
Installation position
Alarm contact:
-
Contact rating
-
Internal resistance
-
Contact position
Fault contact:
-
Contact rating
-
Internal resistance
-
Contact position
Tamper contact:
-
Contact rating
-
Internal resistance
-
Contact position
Protection category as per EN 60529
Environmental class as per VdS
Operating temperature range
Storage temperature range
Dimensions W x H x D
Colour
. After max.
Red
Yellow
What
When power on
Motion detected
Covering detected
Failed self test
1)
Alarm
12 V DC
8.0 V to 15 V DC
6.6 mA
8 / 11 / 13 / 15 m
PIR and MW together
temperature-compensated
normal / high
up to 30 cm
9.35 GHz (X band)
10.587 GHz (X band)
+14 dBm EIRP max.
+14 dBm EIRP max.
vertical, optics at bottom
15 V DC / 0.1 A
£
W
25
open in the event of alarm
15 V DC / 0.1 A
£
W
25
open in the event of fault
15 V DC / 0.1 A
£
W
10
open in the event of tamper
IP 30 / IK 04
II
-10 °C to +55 °C
-25 °C to +70 °C
64 x 158 x 48 mm
Traffic white
(similar to RAL 9016)
The PIR detector recognizes movements in response to the temperature difference
between a person and the background of the room.
Observe while performing a walk test: There would be different ranges for the monitored
area / detection coverage depending on environment conditions. The walk test should be
done under realistic conditions, at this the clothes of the person and the room temperature
do mostly influence the accurateness of the detection.
To have some reserve even under extremely unfavourable conditions, the detector should
be set to a higher detection range or a second PIR detector should be installed.
Walk test in Easy Logic mode:
The detector is automatically in walk test mode for
completed. Conduct the walk test within this time period. LED indication see 7.
The detector is operationally ready after the 10 minutes have expired.
To activate walk test in normal operating mode, disconnect operating voltage briefly
connect input "T" to 0 V (see 4.2).
Indication reset
After 30 sec.
Automatically without motion
When covering is removed
When fault is eliminated
2)
Reset signal from control panel
9.
Accessories
033390.17 Adjustable joint
Swivel range: Horizontal
as per EN grade 2
033588.17 Ball-and-socket set for wall and corner mounting
Swivel range: Horizontal ±45°, Vertical ±20°
not as per EN
033391.17 Seal
(PU = 20 piece)
10.
EU conformity
Hereby, the Novar GmbH declares that the radio equipment Viewguard
DUAL AM FAI, Item no. 033440.01/ 033450.01 and Viewguard DUAL FAI,
Item no. 033441.01 / 033451.01 is in compliance with Directive
2014/53/EU.
The full text of the EU declaration can be downloaded from our homepage
https://www.security.honeywell.de/ in the service/download area.
The devices may only be sold and operated in the following countries:
033440.01 / 033441.01:
DE,AT, CH, LI, PL, SK, CZ, LU, TR, GR, LT, HU, BE, NL, BG, RO.
033450.01 / 033451.01:
GB, FR, ES, IT, PT, DK, NO, BG, RO
11.
Approvals
033451.01 Viewguard DUAL FAI
EN 50131-1 and EN 50131-2-4: 2008-10,
Security grade 2, Environmental Class II
033450.01 Viewguard DUAL AM FAI
EN 50131-1 and EN 50131-2-4: 2008-10,
Security grade 3, Environmental Class II
The standards EN 50131-2-4 are certificated by:
VdS Schadenverhütung GmbH
Zertifizierungsstelle
Amsterdamer Str. 174
D-50735 Köln
Subject to change without notice
approx. 10 minutes
after initialising is
1)
A)
No LED
indication in
Easy Logic
B) With FAI logic: The LED flashes on the detec-
tor that triggers first (see 4.3 "FAI logic")
2)
See table in Chapter 4.3
"Function of inputs", function c).
±20°,
Vertical +4° up to -8°
3
or
mode

Publicité