Installation Instructions

GB
Viewguard Series DUAL
1.
Introduction
The Viewguard DUAL motion detector comprises two systems that operate fully
independently: Passive infrared detector plus Microwave detector. The functioning principle
of the detector is based on the intelligent linkage of a passive infrared sensor and
microwave. This type of linking renders the detectors particularly insensitive to air and
thermal turbulences. (Microwave module see Fig.
They are delivered with the following main features:
5
-
Volumetric mirror optic
(see Fig. 3- , Fig. 6)
-
Anti-masking up to 30 cm from the detector
-
Microwave sensor inactive in the "disarmed" state.
-
FAI (First Alarm Indication):
When multiple detector on a single zone, Indicate the first detector in alarm
-
Selectable range and sensitivity
-
Memory function
-
Selectable range and sensitivity
-
Self-test
(only AM detectors)
-
Monitoring of operating voltage
-
Tamper and back tamper
2.
Installation Guide line
Maximum sensitivity is achieved when mounted crosswise to the horizontal detection
zones of the PIR sensors. Therefore, select a mounting site that runs crosswise to the
expected direction of motion. (See Fig.
6-A
Due to the additional microwave, the dual detector has a very high detection capacity even
with diagonal movement. (See Fig. 6-B).
Minimum distance to ceiling: 2 cm
Avoid:
* Mounting above radiators
* Mounting near air discharge openings (e.g. air conditioning systems)
* Direct sunlight
* Mounting near to fluorescent lamps
* Mounting near to light bulbs
3.
Installation
Open housing
(see Fig. 1)
If necessary, break the seal with a small screwdriver or similar object and pull downward
1
. Press the notch (at the bottom in the middle, see Fig.
3
press off the front of the housing
. Lift off the housing front
Mounting options
• 0° Vertical
• Vertical at a 3° downward angle
• Horizontal at a 45° angle to the left or right
• Corner mounting
The detector can be mounted by using the optional swivel bracket (see "Accessories").
Recommended mounting height 2.5 m for optimal operating sensitivity.
If the detector is not mounted at the recommended mounting height, this will have a negative
effect to the monitored area. In this case please get in contact with our technical support.
Carry out a walk test for each detector in all cases
Cabling, strain relief
(See
Fig.
4)
A
For surface mounted wiring
B, C
For flush mounted wiring
C
For use with adjusting hinge
D
For strain relief with cable strap
Backtamper
(see Fig. 4)
Required for installation according to EN 50131-2-4 grade 3.
The backtamper can be used if installed as illustrated in Fig. 5/1, 5/2, 5/3a, 5/3b and 5/4.
a
Tappet for backtamper. Remove the pin at the tappet, if the backtamper is
being used (see illustration)
b
Protective cover for back-tamper (on the rear). Remove, when mounting as
per Fig. 5/3a or 5/4
1
3-
).
3
, see Fig.
2-
,
(only AM detectors)
).
5
2-
) slightly inward
4
.
Screw on position
1
see Fig. 5/1
Fig.
4-
2
see
Fig.
5/2
Fig.
4-
3
see
Fig.
5/3
Fig.
4-
1
see
Fig.
5/4
Fig.
4-
(see 6.3).
4.
Connection diagram, operating modes
4.1
Terminal
Fault Tamper Alarm T U F - +
Spare terminals for
end of line resistors
The connection of the inputs "T", "U" and "F" depending on the operating mode (see 4.2 and 4.3)
4.2
Easy Logic operating mode
Note:
In this operating mode no alarm indication is available.
Microwave sensor always active.
Anti-Mask function always active
Minimum of required connections: Alarm output and operating voltage (= 4 wires).
The usage of the "Walk test" input is optional. The detector is automatically in walk test mode
for 10 minutes after applying the operating voltage (see 6.2 and 6.3).
T U F - +
DIP-switch setting:
4.3
Viewguard operating mode
T U F - +
In viewguard mode, microwave part of the sensor will be deactivated when input "U" will be
connected to 0V (panel disarmed). See table "Operating mode" below.
FAI logic:
(FAI = irst larm ndication, usage optional)
F
The FAI connections "F" of all detectors are connected to one another. A connection to the
control panel is not required. The LED
light on
the subsequently triggered detectors (see 7. "LED indication").
2
and
DIP-switch setting: (position see Fig. 3-
Operating mode:
S4
S6
Mode (
ON
OFF
Viewguard mode,
OFF
OFF
Viewguard mode,
ON
ON
Easy Logic mode, see 4.2
OFF
ON
Not allowed
Memory for AM function:
(only AM detectors)
S5
Mask
ON
Not memory
OFF
Memory
Reset memory: - Remove cause
- Activate walk test (inputs "T" and "U" 0 V)
- Trigger detector
- Finish walk test mode
5.
Set range and sensitivity
S1
S2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
PIR and MW operate automatically
with the same range.
Installation Instructions Viewguard DUAL / AM FAI
If the control panel has no fault input,
the "Alarm" and "Fault" outputs can
be connected in series.
Fault Tamper Alarm
(only AM detectors)
Function of the walk test input "T":
open
Normal operation
0 V
Walk test mode (see 6.3)
osition see Fig.
S4, S5 and S6 in position
"ON"
(p
Function of inputs: (Pull-up resistors in the detector)
Inputs
Walk test "T" Arm/disarm "U"
open
open
open
0 V
0 V
0 V
A
I
flashes
on the detector that triggers first, the LED
3
)
Anti-Mask only AM detectors
)
Anti-Mask always active
Anti-Mask inactive in "armed" state
Not memory:
(recommended operating mode)
Anti-Mask will automatically be resetted when
finishing walk test mode.
Memory:
(only required for VdS applications)
Mask signal remains saved in the detector until
resetting (see below).
(inputs "T" and "U" open)
Range
S3
8 m
ON
11 m
OFF
13 m
15 m
3
)
3-
Function
a) armed
b) disarmed
c) walk test (see 6.3),
reset alarm indication
.
Sensitivity