Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
73858000 / 73866000: Only dishwashers and
washing machines certified with the DVGW emblem
may be connected to the appliance connection
valve without an additional fuse. If no consumer is
connected to the appliance connection valve, it must
be plugged.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded base - connection hoses not completely
Hot water temperature too low
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
screwed into basic body
- O-ring at the connection hose defec-
tive.
- Hot water limiter incorrectly set
Assembly (see page 6)
English

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 10)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Operation (see page 11)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning (see page 12)
Dimensions (see page 13)
Flow diagram (see page 15)
Spare parts (see page 16)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Test certificate (see page 18)
Rate of flow mixer
Rate of flow stop valve
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter

Publicité