In the event of a power cut while programming the ends of travel, (LED blinking),
The PLC continuously monitors operation of the AQUAMAT 3001 motor. In the event of an
anomaly, the motor stops and the LED blinks a specific code sequence:
The LED remains lit for 5 seconds, then blinks a certain number of times before remaining lit
again for 5 seconds. Count the number of times the LED blinks, this number corresponds to an
error code:
-Error 1:
Read error. The programme cannot read the slat apron position.
Cut the power supply and reenergise. If the problem persists, replace the electronic
board.
- Error 2 : Write error. The programme cannot save the slat apron position.
Cut the power supply and reenergise. If the problem persists, replace the electronic
board..
- Error 3 : Electronic sensor fault. Check the connections of the shielded cable linking the motor
and control panel. Check the coding wheel and the sensor in the motor.
- Error 4 : The motor is turning in the wrong direction. Inverse the + and - wires between the
control panel and the motor.
- Error 5 : Not in use.
- Error 6 : Key error. The motor turns while the key is in the "0" position. Cabling error or short
circuit in the control panel.
Remain vigilant while operating the motor.
Before operating the motor, check:
- that there is no-one in the pool before you close the cover.
- that no floating object or automatic cleaner could impede the movement of the slap apron.
- that the water level is correct (not too high, not too low).
Keep watching while the slat apron while it is in motion.
MAINTENANCE•AND•WINTERIZING
The AQUAMAT•3001 motor does not require any specific maintenance. Simply check that the pit in which
the motor is installed is not too wet or full of water.
During winter, the motor should be removed from the pit once the cover is rolled out over the pool :
- Unscrew the quick fit connectors and pull them our of the motor leaving the box mounted on the wall.
- Remove the U-shaped pin by pulling upwards and take out the AQUAMAT 3001 motor.
- Store the motor in a location protected against bad weather and humidity.
To reconnect the motor, carry out the same procedure in the reverse order and programme the ends of
travel.
CAUTION
no information will be saved to memory.
Recommence programming from the beginning.
OPERATING•ERRORS
RECOMMENDATIONS
15/16