English
Mark a point on each nipple ⅝" from the surface of
the finished wall
Carefully cut the nipple at this point.
Installation
Seal the wall around the nipples with
waterproof sealant.
Flush the hot and cold supplies thoroughly
Damage to the Ecostat Select caused by debris is not
coverd by the Hansgrohe warranty.
Wrap the nipples with plumbers' tape.
Install the adapters.
Over-tightening the adapters may
cause damage to the adapters or to
the nipples.
The adapters should extend 1½" outside the surface
of the finished wall.