LaserLiner ThermoCamera Connect Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.9
Settings: Version
Settings
Auto shutdown
Intensity
Language
Time format
Set time
Spot
WLAN
Image correction
Version
6.0
Emissivity
Before each use, check the settings for infrared measurement and adjust them to the respective
measuring situation to ensure accurate measurements. Pay particular attention to the general
parameters for the emissivity coefficient.
6.1
Emissivity: Emissivity coefficient
The level of infrared emissions given off by everything depends on the specific material and surface. This
factor is determined by the emissivity coefficient (0.10 ... 1.0). For accurate measurements, it is absolutely
essential that the emissivity coefficient is set first. The emissivity coefficient can either be custom set or
selected based on the predefined emissivity coefficients from the material list.
Images
Color palette
Emissivity
Settings
Emissivity
Matt (e=0.95)
Semi-matt (e=0.85)
Semi-gloss (e=0.60)
Glossy (e=0.30)
Individual
Version
V 2.3.7
Increase value
Decrease value
0.95
5
ThermoCamera Connect
Emissivity
Matt (e=0.95)
Semi-matt (e=0.85)
Semi-gloss (e=0.60)
Glossy (e=0.30)
Individual
0.95
Confirmation
Exit menu
21
EN

Publicité

Table des Matières
loading

Table des Matières