Velleman HAA85WP Notice D'emploi page 5

Clavier de securite a divers usages
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. Keyboard Illumination LED
The keyboard illumination LED lights up for 10 seconds when a key button is pressed, which indicates the duration of
the allowable time for each digit of continuous code entry. The digit of code entry is invalid beyond the allowable time
when the LED lamp is off.
7. Factory Set Data
For the owner's convenience in programming at the first time, the factory has put a MASTER CODE 0000 into the
keypad. Except that code, no other useful code or data has been put into the keypad. The owner has to put his own
UNIQUE CODES and DATA into the keypad before use.
8. Important Note to Owner
To compromise security, in all cases, the owner should program a PERSONAL MASTER CODE for his keypad in
order to invalidate the factory set 0000 Master Code.
9. Programming the Keypad - Example
1) REQUIREMENT -- The following data are required to be stored:
a) Change the factory set Master Code 0000 to a Personal Master Code 3289
b) Set User Code 1 in 8321
c) Set User Code 2 in 6854
d) Set User Code 3 in 9270
e) Set Output 1 in Momentary Mode, 5 seconds
f) Set Output 2 in Start/Stop Mode without accelerated code
g) Set Output 3 in Start/Stop Mode with accelerated code
h) Set the keypad to lock itself during 30 seconds after 10 successive false codes
2) PROGRAMMING -- Put the required data above into the keypad
0 0 0 0
0
3
2
8
1
8
3
2
2
6
8
5
3
9
2
7
4
0
5
#
5
1
#
6
2
#
7
0
#
*
Note: In case of wrong entry during programming, cancel it with key #, or wait 10 seconds, then re-enter.
HAA85WP
Enter in programming mode by the Factory Set Master Code.
*
3289 has been stored as the new Personal Master code &
9
#
Super User code.
8321 has been stored as User Code 1 & Duress Code.
1
#
6854 has been stored as User Code 2.
4
#
9270 has been stored as User Code 3.
0
#
Relay output 1 has been set in Momentary Mode, 5 seconds
Relay output 2 has been set in Start/stop Mode without
accelerated code.
Relay output 3 has been set in Start/stop Mode with
accelerated code.
Keypad has been set to lock during 30 seconds after 10
successive false codes.
Programming is finished. All the data above have been
stored and ready for use.
5
VELLEMAN

Publicité

Table des Matières
loading

Table des Matières