This manual is a reference guide for Carlo Gavazzi Loop Detector LDP1 and LDP2. It describes the product
specifications as well as how to install, set up and use the product for its intended use.

1.1 Description

Carlo Gavazzi Loop Detectors are devices designed and manufactured in accordance with IEC international
standards and are subject to the Low Voltage (2014/35/EU) and Electromagnetic Compatibility (2014/30/
EU) EC directives.
All rights to this document are reserved by Carlo Gavazzi Industri: copies may be made for internal use
only. Please do not hesitate informing us to make any suggestions for improving this document.

1.2 Validity of documentation

This manual is valid only for LDP1 and LDP2 Loop Detector and until any newer documentation is published.
This instruction manual describes the functions, operations and installation of the product for its intended
use.

1.3 Who should use this documentation

This manual contains important information regarding installation and must be read and completely
understood by specialized personnel dealing with these kinds of devices.
We highly recommend that you read the manual carefully before installing the Loop Detector. Please save
the manual for future use. The installation manual is intended solely for qualified technical personnel.

1.4 Use of the product

The Loop Detector is primarily used to detect vehicles such as cars, trucks, buses and others.
A loop in the ground is required for the Loop Detector to detect any vehicles above the loop. The device
works on the same principle of an inductive sensor; utilizing the phenomenon of eddy current. When a
metal target/vehicle approaches on top of the loop, the magnetic field generated by the loop interacts with
the target and makes the Loop Detector to change its output.
The Loop Detector can be used at carpark barriers, bollards, gates, toll gantries and many other door
access applications.

1.5 Safety precautions

This Loop Detector must not be used in applications where personal safety depends on the function of the Loop
Detector.
Installation and use must be carried out by trained technical personnel with basic electrical installation knowledge.
The installer is responsible for correct installation according to local safety regulations and must ensure that a
defective Loop Detector will not result in any hazard to people or equipment. If the Loop Detector is defective, it
must be replaced and secured against unauthorized use.

1.6 Other documents

It is possible to find the datasheet, manuals, brochures and electrical drawings on the Internet at
http://gavazziautomation.com
4
Rev.00 - 01.2019 | LDP1/LDP2 Single and Dual Loop Detector | © 2018 | CARLO GAVAZZI Industri

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ldp2pa2du24

Table des Matières