Main functions
______________________________________________________________________
Self-test
Switch ON the machine by pressing the power switch on the back. In the main display you can see „0" after self
checking.
Automatic start
The banknote counter will start the counting process as soon as banknotes are put onto the hopper.
Manual start
The banknote counter will start the counting process as soon as banknotes are put onto the hopper and pressing
„RESTART" - key. For activating the manual counting start, please press „MN" - key.
Counting modes
Free counting mode
The device counts all banknotes on the hopper.
Batch mode
Press the „BATCH" - key for activating the batch function (several times for adjusting standard
bundles). For adjusting individual bundles, please press the keys „+" or „-".
By reaching the setted batch number, the machine will stop counting automatically.
Sheet counting mode
When valuecounting mode is deactivated („VALUE" - key), the message „TOTAL VALUE" will not be illuminated
in the display. The device will now count the quantity of the bills on the hopper.
For activating the size detection (DD and 3D), please press the „SORT" - key.
Value counting mode
When valuecounting mode is activated („VALUE" - key), the message „TOTAL VALUE" will be illuminated in the
display. The device will now count the quantity and the value of the bills on the hopper.
For checking the quantity of each single denomination after counting, please press „REPORT" - key.
Ultraviolet detection
For activating the UV - detection, please press the „CF" - key. When suspected notes are recognized, the
machine stops automatically and will show the error message „A" on the display.
Please remove the suspected banknote and count all notes again.
Magnetism detection
For activating the MG - detection, please press the „CF" - key. When suspected notes are recognized, the
machine stops automatically and will show the error message „b" on the display.
Please remove the suspected banknote and count all notes again.
Adding several results (ADD)
To add several counting results, please press the „ADD" - key for activating the addition mode.
For deactivating the addition mode, please press the „ADD" - key again.
Menu (SET)
For activating the menu, please press the „SET" - key. In the menu, you can adjust the following parameters:
A = Intensity of UV - detection
b = Intensity of MG - detection
C = Intensity of chain - detection
E = Intensity of IR - detection
d = Intensity of size - detection
10