OPERATING INSTRUCTIONS CONT-

5.17 Low Resolution Mode

5.17.1 In the Normal Resolution mode, the extremely high resolution of the scale may lead to
noticeable, yet small, fluctuations in the reading caused by weight shifts or wind. To
alleviate this a Low Resolution mode may be activated.
5.17.2 Press and hold the KG/LBS Key for 3 seconds. The unit of measure enunciator will
begin to flash.
5.17.3 Release the Key. Resolution is now reduced by a
factor of 5 (1.0 oz./.050 Lbs./ 20g) and will provide stable readings under extreme
conditions. To return to the normal resolution mode, depress the KG/LBS Key again
and hold until the enunciators stop flashing.

5.18 Back Light

Holding the MODE Key down for 3 seconds will enable the Back Light feature.
To disable the Back Light, hold down the MODE Key until the light goes out.
6.

MAINTENANCE

6 .1

Battery Installation

6.1.1 Remove the battery cover located on the backside of the Control Box.
6.1.2 Install a 9-volt alkaline battery in the battery clip and store it in the lower section.
6.1.3 Install 4 each "AA" 1.5-volt batteries in space provided. The polarity is indicated in
the bottom of the compartment.
6.2

Cleaning Port Filters

6.2.1 The 9055 inlet and outlet ports contain fine mesh screen filters to prevent dirt or
particulate from entering the valve and causing the seat to leak. In the event that you
noticed reduced flow through the valve, or if you have recovered dirty/contaminated
refrigerant, it is recommended that these filters be cleaned.
6.2.2 To clean the filters: Turn the unit on, press SET; enter an amount, press SET and
then the GO key to open the valve.
6.2.3 Connect a source of clean and dry shop or compressed air (80-100 psi recommended)
to the OUTLET (right) port.
6.2.4 Warning: Ensure that the INLET (left) port is pointed away from yourself and others,
then turn on the source and allow the compressed air to run backwards through the
valve for several seconds.
6.2.5 Remove the air source and turn off the 9055.
7.

REPLACEMENT PARTS

1/4" FFL to 1/2" ACME Male adapters
Replacement Battery Door
p/n TIF9021
p/n 100366