Les langues disponibles

Diagnostics
Light ring lights up
RED
Light ring lights up
GREEN
Light ring lights up
BLUE
Light ring does NOT
light up
Diagnostics complete
Press and hold
until the light ring lights up
ORANGE. Release the button immediately
Check whether hot water is being dispensed
No hot water being dispensed:
Check hot water supply pipe
- Is the hot water supply pipe open?
- Is the water treatment active?
- Is the dirt filter working properly?
- Is the cold and hot water supply connected
correctly?
Check whether NO water is being dispensed
If water is being dispensed:
- The controller is faulty; please contact
Schmidlin Service.
Check whether cold water is being dispensed
If cold water is not being dispensed:
Check the cold water supply pipe
- Is the cold water supply pipe open?
- Is the dirt filter working properly?
- Is the cold and hot water supply connected
correctly?
Check the electrical connection between the
controller and the control element. If the fault
cannot be rectified, please contact Schmidlin
Service.
Flashes ORANGE twice: Diagnose abgeschlossen,
Funktionsüberprüfung erfolgreich.
Flashes ORANGE three times: Fehlfunktion
der Temperatursensoren. Schmidlin Service
kontaktieren.
Flashes ORANGE four times: Fehlfunktion
der Durchflusssensoren. Schmidlin Service
kontaktieren.