F. Reset master code
On stand-by operating mode,
put a jumper on P2.
- Wait 1 second and then remove the jumper.
- One beep is emitted.
- The master code is restored to its default
value 1 2 3 4 5 in 5-digits code and 1 2 3 4
in 4-digits code.
G. Changing the code by a user
To authorize a user to modify its own
User code place the jumper on P3
(to disable the function remove the jumper).
1. Enter the old user code.
The relay is activated and a beep is emitted.
2. Enter the 2-digits sub master code
(default sub master code AB).
A beep is emitted to authorise the modifi cation.
3. Enter the new user code.
2 beeps are emitted to confi rm
the new code.
4. Check the new user code to be sure
of the modifi cation.
H. Setting a sub master code
The Sub Master code allows the user
to change its own code without entering
in programming mode. For security
reasons the code need to be changed
periodically. This feature makes it easier
and faster to change its code.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm entry
in programming mode.
2. Press A7 to program a sub master
code for the user individual Pin
code modifi cation.
- One beep is emitted.
- Enter the new 2-digits sub master code.
- One beep is emitted to confi rm
programming of the sub master code.
cdvi.com
16
cdvigroup.com
3. Press B to exit
from the programming mode.
2 beeps are emitted to confi rm that the
keypad is in stand-by operating mode.
I. Audible Feedback
The audible signal is enabled in programming
mode and when the relay is energised
after a valid code. To enable the audible
feedback on a key press:
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm entry
in programming mode.
2. Press AA.
- One beep is emitted.
- Press 0 to disable the audible signal
during a keypress.
- Press 1 to enable the audible signal
during a keypress.
- One beep confi rms the new setting.
3. Press B to exit from programming.
2 beeps are emitted to confi rm exit
from programming mode.
J. Use of the red and green LEDs:
- The red and green LEDs are designed
to receive 12V dc (built-in resistors),
- They are wired as follows:
Red LED
2.2KΩ
Green LED
Orange
2.2KΩ
12V dc
Gray
0V
Pink
12V dc
Blue
0V