Pump Specifications; Electrical Requirements - Xylem LOWARA Resiboost MMW09 Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
Table 12: MMA and MTA standard versions
Converter mod-
MMA
el
06...
Rated voltage
1x230V (–20% to +10%)
input (Uin)
Rated voltage
1x(0-100%)Uin
output (Uout)
Rated input fre-
quency
Output frequen-
cy
Rated input cur-
6,3A
rent
(Uin-230V)
Rated output
6A
6
current
(Uout=230V)
Overcurrent
20%, 10 second maximum
Recommended
13A
7
line protection
Consumption in
standby
Type of load
Nominal cosφ
≥0,60
(motor)
IP protection
Maximum power
cable section
Maximum motor
power cable
section
Set-point pres-
0,5 to 16 bar (50 to 1600 kPa)
sure
Ambient tem-
0 to 40°C (32 to 104°F)
perature
Ambient humidi-
< 50%, non-condensing
ty
8
Elevation
Protection fuse
10A
(inside)
Cooling
Natural
air
Auxiliary power
supply of pres-
sure sensor
Digital input for
float switch con-
tact
Dimensions and
See
weight

3.4 Pump specifications

MMA
MTA
MTA
12...
06...
10...
3x(0-100%)Uin
50±2 Hz
15-50 Hz
12,6A
11A
18A
12A
6A
10A
16A
16A
25A
4W
electric motor
≥0,75
54
2
2,5mm
2
2,5mm
≤2000m asl
16A
16A
20A
Forced
Natural
Forced
air
air
air
15Vdc
24Vdc, 23,9mA
Figure 5
(page 244).
Refer to the user and maintenance manual of the
electric pump. It is essential to consider the limita-
tions of use of the converter together with those of
the electric pump. See
Technical data
The customer is responsible for checking the limita-
tions of the electric pump if they are not specified in
this manual.
4 Installation
Precautions
WARNING:
• Observe accident prevention regula-
tions in force.
• Use suitable equipment and protec-
tion.
• Always refer to the local and/or na-
tional regulations, legislation, and co-
des in force regarding the selection of
the installation site, plumbing, and
power connections.

4.1 Electrical requirements

• The local regulations in force overrule specified
requirements listed below.
Electrical connection checklist
Check that the following requirements are met:
• The electrical leads are protected from high tem-
perature, vibrations, and collisions.
• The current type and voltage of mains connec-
tion must correspond to the specifications on the
data plate on the pump.
• It is suggested to supply power to the converter
with a dedicated power line and it is provided
with:
– A high-sensitivity differential switch (30 mA)
[residual current device RCD] suitable for
earth fault currents with pulsating content. In-
terrupter must be marked with the following
symbol:
ELCB
(GFCI)
Refer to
Figure 11
MMW, MTW
andFigure 12
models MMA, MTA.
– A mains isolator switch with a contact gap of
at least 3 mm
The electrical control panel checklist
NOTICE:
The electrical panel must be compatible with the da-
ta of the electric pump powered by the converter. In-
appropriate combinations do not guarantee the pro-
tection of the unit.
Check that the following requirements are met:
• The control panel must protect the converter and
the pump against short circuit. A time lag fuse or
a circuit breaker (Type C model is suggested)
can be used to protect the pump.
• The converter must be programmed correctly to
protect the pump from overloading. Refer to
en - Original instructions
(page 26).
(page 247) for models
(page 248) for
27

Publicité

Table des Matières
loading

Table des Matières