Sanitary-Grade Acrylic; Cleaning; Damage; Controls - DURAVIT Combi-System E Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
7.2

Sanitary-grade acrylic

Cleaning

> Clean acrylic with a soft, damp cloth.
> Use the Duravit Maintenance Set for Acrylic Surfaces for the occasional thorough
cleaning and for removing stubborn spots.
> Remove extensive soiling with warm water and a liquid detergent, dish washer
liquid or soap suds.

Damage

> Remove scratches and other surface damage with the Duravit Acrylic Surface
Maintenance and Repair Set (ID No. 790302 00 0 00 0000).
7.3

Controls

> Clean the controls with a soft, damp cloth.
7.4

Drain and overflow fittings

> Clean the drain and overflow fittings with a soft, damp cloth.

8. Troubleshooting support

CAUTION!
The whirlpool tub may only be repaired by qualified plumbers and electricians.
Problem
Potential cause
Foaming
Soap or shampoo in the
bathwater.
Whirl system won't
Water level too low.
start?
Mains switch switched off.
32
Solution
>
Switch off the whirlpool
system.
>
Fill the tub with fresh water.
>
Add water until the water
level is about 5 cm above the
uppermost nozzle.
>
Switch on at mains.
Problem
Potential cause
Mains fuse is switched off.
Ground-faultswitch (RCD) or
circuit breaker has tripped.
After the water is
The floor nozzles' blower au-
drained, the air nozzles
tomatically starts a 2-minute
start automatically and
drying mode to remove any
the "Air" button flashes.
remaining water from the lines.
Sound of motor during
Residual water drain lines are
filling / after draining
being opened / closed.
the tub (with Blue Moon,
2nd floor series).
There are 4 short signal
UV Hygiene Management is
tones when activating
defective.
the jet nozzles.
There are constant
UV Hygiene Management is
short signal tones when
defective.
activating the jet noz-
zles.
Sound volume / quality
Data not compatible.
cannot be changed.
"Jet" button flashes:
1x
Water level too low
2 - 4x and vibrates
Whirl system defective.
5x and vibrates
Temperature sensor
defective.
! Do you want to acknowledge the error message?
> Press the corresponding button for 2 sec. The button stops blinking. The whirl-
pool is restarted but the error message appears again.
Solution
>
Switch on mains circuit
breaker.
>
Disconnect tub from mains.
>
Call Customer Service.
>
Call Customer Service.
>
Report number of signal
tones.
>
Disconnect tub from mains.
>
Call Customer Service.
>
Report number of signal
tones.
>
Check whether the audio
source supports the A2DP
protocol.
>
Add water until the water
level is about 5 cm above the
uppermost nozzle.
>
Call Customer Service.
>
Report number of flashing
signals.
>
Call Customer Service.
>
Report number of flashing
signals.
33

Publicité

Table des Matières
loading

Table des Matières