Electrical installation instructions

Information for installing pool electrical connection
1. Supply line / main cable
Connection according to DIN VDE 0100-702 using securely laid cable NYY-J 3x2.5 mm²,
RCD protection at house outlet <=30mA, preferably buried, and introduction to the plant
room at ground level. All-pole safety door contact on the door to the plant room to isolate the
loads from the main cable when the door to the plant room is opened.
2. Supply lines to the loads at the pool
IPx5 distributor housing with terminals for max. 2 loads, one of which is the filter system. A
circuit breaker for the filter system, integrated in the distributor housing
Safety and warning information for electrical installation
Check the location of the electrical connection before installing the pool.
The pool's electrical connection is to be via a securely laid cable NYY-J 3x2.5 mm², without connectors.
The cable is to be protected with RCD protection (FI circuit breaker <= 30 mA) at the connection point
with the house. (DIN VDE 0100-702.55.4 is to be noted.)
Recommendation:
Installation of an all-pole disconnect switch with upstream protection by means of 16 A automatic
cut-out.
Laying and connection of the supply cable must be in accordance with DIN VDE 0100 Part 702.
Before installing the pool, clear the electrical connection with a specialist electrical company.
The supply cable, the supply line(s), the filter pump and the separator must be installed in such a way
that protection equivalent to protection rating II or with equal insulation is provided.
The electrical installation work in the plant room is to be carried out by a qualified electrician according to
the attached connection diagrams.
Connectors are not permitted within 3.5 m of the pool.
Only devices and equipment certified and approved for the operating conditions may be connected to the
electrical distribution in the pool's plant room. The connection must be carried out by a certified
electrician.
The safety door contact is used to switch off all active conductors when the door to the plant room is
opened.
Key to connection diagram
1. Supply line from the house distribution (fixed connection) via FI circuit breaker <= 30 mA
2. External all-pole safety door contact IPX5
3. External switch for filter system IPX5
A. Filter system
B. Reverse current unit
Manufacturer:
weka Holzbau GmbH
Johannestr. 16
D-17034 Neubrandenburg
Tel.: (0049)-395 429080
Fax. :(0049)-395 4520883
Technische Änderungen vorbehalten!
Alle Maßangaben sind ca. Maße.
1
 Copyright HRB 3662

Publicité

loading

Ce manuel est également adapté pour:

593.5060 série594.4070.00 série594.4085.00 série