Instructions For Assembly And Use - Geba Tronic Cody T4 Mode D'emploi Et Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Assembly Instructions
Assembly of the CODY keypad:
1. By slightly pushing the two latches at the right and left side of the keypad
from behind to the edge, remove the small frame from the keypad.
2. Now you see two fixingholes (diam. = 4 mm) at the front of the keypad.
By means of these you can fix the keypad onto the wall.
3. Connect the keypad to the logic unit by means of the twin-cable (up to 5 m long).
There is no particular polarity for the twin wires.
4. Now re-fix the small frame.
5. It is possible to connect in parallel up to four keypads if a thin connection cable, max.
2
total line cross-section 1.5 mm
, is used.
Keypads connected in this way must not be operated simultaneously.
Assembly of the logic unit (inside area):
1. Put the screw-driver into the gap of the enclosure front, push the screw-driver up and
open the enclosure.
2. Remove the control PCB (which is force fitted to the inside of the enclosure).
3. Locate the screwed glands supplied (sealing nipple left side) in the
enclosure and replace the PCB. (Please ensure PCB is firmly in position)
4. Bore the fastening holes and fix the enclosure bracket at the wall.
5. The wires for the keypad ensure through the left cable entry (sealing nipple), the wires
for the relay contact through the middle cable entry and the wires for the supply voltage
ensure through the right cable entry. Ensure tight seating of sealing nipple and cable
gland, otherwise the water-protection ot the appliance cannot be assured.
6. According to connection diagram connect the wires to the corresponding terminals.
geba GmbH is released of its obligations regarding guarantee and product liability if - without prior
permission - the unit has been modified, or if the installation is improper or not in accordance with
our instruction manual.
The installer has to take care that the EMC-regulations are respected.
®
industrial controls
Electronic encoder-type lock for electric door-openers
The TCS-Cody-T4 is a modern and safe keyless door-opening system. The TCS-
Cody-T4 can safely be used after programming the pass code. For opening the
door only a four- or five-digit numeral code (pass code) has to be entered
After correct input of the pass code and pushing the key button the electric door-
opener is activated.
The most important characteristics of the TCS-Cody -T4 are:
⇒ ⇒
⇒ ⇒
⇒ ⇒
⇒ ⇒

Instructions for Assembly and Use

TCS - Cody - T4
Simple operation, programming and assembly.
Water-protected enclosure.
A maximum of safety:
⇒ ⇒
The electronic decoder is separately installed in the
protected area
⇒ ⇒
4 different pass codes can be stored
⇒ ⇒
Nearly unlimited data security, even with power failure
Direct connection of electric door-opener.
®
industrial controls
GB