Connecting the radio module
Switch off the mains electricity supply before carrying out
any work. Electrical connections must be made by a
qualified professional.
It is possible to connect a radio module to each control panel.
Heating generators installed in cascade: one radio module per
appliance is required.
1. Access to the SCU PCB.
Refer to the installation and maintenance instructions of the
heating generator (Electrical connections).
8
The radio module must be fixed to the wall close to the heating
generator to enable its connection to the control panel. Use the 4
screws + 4 plugs provided.
Do not mount the radio module close to metal walls or
partitions.
Do not mount the radio module in the heating generator.
3
C002446-B
2. Connecting the radio module to the terminal block corresponding
to a circuit's room sensor (S.AMB A, S.AMB B, S.AMB C).