Qlima SRE 10x TC Manuel D'utilisation page 59

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
J: A blinking VENT indi-
cator is a sign that you
need extra ventilation.
Fuel filter
K
Once the heater has used up all its fuel and is extinguished it will take some time,
after the refill, before the heater is completely ready for use again.
K
THE 'VENT' INDICATOR
When there is insufficient ventilation in the room, the heater shuts off automatically.
When this occurs, the VENT indicator is blinking. After improving the ventilation of
the room (e.g. by opening a door or window a little more), the heater can be ignited
by pushing the button L again.
L
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
work. Also disconnect the plug from the mains. Your heater needs hardly any
maintenance. It is, however, important that you clean the vent filter 8 with a
vacuum cleaner and the grid 2 with a damp cloth, both on a weekly basis.
Regularly inspect the fuel filter as well:
1
Remove the removable tank 6 from the heater and remove the fuel filter
(Fig. K). Some drops may leak from the filter; keep a cloth at hand.
2
Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(never clean it with water!)
3
Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains from time to time with a damp
cloth, because otherwise these may cause stains that are hard to remove.
Do not remove any heater components yourself. Always contact your dealer for
repairs. When the power cord is damaged, it may only be replaced by an autho-
rised fitter. Use a new cord of the type H05 VV-F.
M
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local regu-
lations for the disposal of domestic chemical waste.
Always start the new heating season with fresh fuel. When you start re-using the
heater follow the instructions again (starting from section A and as specified).
N
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
1
Let the heater cool down.
2
Remove the removable tank 6 from the heater and remove the fuel filter
(refer to Section L, Fig. K). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
4
59

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières