Lubricating the gear racks
The gear rack drive is optimally supplied with lubricant, using a permanent lubrication system in combination
with a felt cog wheel. The system has been filled with the lubricant UNIVERSAL+. An emptying time of 12
months has been pre-set at the factory. This should be adjusted to an emptying time of 6 months if the
operating time specified in the table has been exceeded in any given year. After this time, the lubricant tank
and the battery must be exchanged. Order description: LUBER DRIVE REFILL 120 UNIVERSAL+. Systems
connected to the machine controls, other lubricants or container volumes can also be used as special
equipment. In this case you should order the lubricant tank from the catalogue or stating the serial number
and battery set (not required for externally controlled systems).
Axis
Modul
AXS120TM280
2
AXS120TM500
3
AXS155TM400
2
AXS240TM500
3
AXS280M200
2
AXS200M200
3
AXS200M250
3
AXS460M250
3
AXS230M320
4
AXS280M400
5
Setting the driving system
The permanent lubrication system is delivered in a switched-off state. Before starting permanent operation,
the system is to be commissioned in accordance with the following description:
Function display
The DRIVE BOOSTER has been equipped with a red and a green LED. The LEDs on the control board may
be viewed through the transparent cover (see Fig. 1). These LEDs inform the operator about the following
operating states and/or faults:
LED
Signal
green
flashing
red
flashing
green and red
flashing
red
intermittent

Setting options

Setting the operating time
The control board has a quad switch for coding.
Switches 1+2 with the description "TIME" can be used to set
the operating time until the LC unit is emptied, while Switches
3 + 4 with the description "VOL" are used to adjust the size of
the LC unit.
km / 120 cm³
80000
64000
80000
64000
40000
32000
32000
32000
29000
24000
Signal duration
every 15 seconds
every 8 seconds
every 3 seconds
continuous
29
Operating state
Operation (OK)
Fault / interrupt
LC unit empty
DRIVE BOOSTER dispensing