Testing The Magnetic Contacts - BASETech 75 18 18 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The magnetic contacts cannot be directly attached to metal frames. If your window or door
frames are made of metal, attach a piece of wood or plastic (at least 1 cm thick) between the
metal and the magnetic contact.
If you want to install the alarm system in a caravan, motor home or boat, replace the mains
electricity supply with the corresponding on-board power supply, such as a 12 volt car bat-
tery.
After the back-up battery (9V block battery) and the plug-in mains power adapter are attached, the movement
sensor "warm up phase" begins and the red "status" LED flashes. After approx. 90 seconds, the "status" LED
ceases to be lit and the system is ready for operation.
After the system has been installed the "walk test" can be carried out. Press the "AWAY" button on the remote
control. The "status" LED lights up as soon as something moves in the monitored area. You can check the exact
range of detection by walking around in front of the sensor.
After the walk test is complete, please leave the room for at least 90 seconds. After a short signal tone sounds,
the system is armed.
When the monitored area of the PIR sensor is entered, the alarm is activated after the short entry delay, irre-
spective of the position of Jumper A.
When monitoring with magnet contacts, depending on the position of Jumper A and B, the alarm is activated
either after a short entry delay or immediately when the magnet contact is opened or breached.

Testing the magnetic contacts

Press the „HOME" button on the IR remote control. This deactivates the motion sensor so that only the mag-
netic contacts are activated.
Wait approximately one minute until you hear a short warning signal. The alarm is now fully activated. To make
sure that the alarm system is fully functional, open a window or a door on which you had previously attached
a magnetic contact. The alarm (internal and external) is triggered. After approximately one minute, the alarm
siren is switched off and the system automatically resets.
You can use jumper A to choose between instant alarm or delayed alarm. If you choose the delayed alarm, you
will hear a warning signal.
If you have set the instant alarm, the siren will sound as soon as the alarm is triggered.
The walk test control light should not blink during the test phase.
If the walk test / status LED lights up, this means that one of the magnetic contacts is not ful-
ly functional. Check all the magnetic contacts and wiring circuits.