REAR PANEL
ALARM DISABLE
MASTER (B) REMOTE
Made in Europe (Fr)
230V
50/60Hz 14W
T 250mA L
A -
Not used.
B -
Balanced stereo MASTER A input (3 pts female XLR)
C -
Balanced stereo MASTER B input (3 pts female XLR)
D -
Balanced stereo output signal (3 pts male XLR)
E -
Alarm remote control relay ON/OFF contact.
(15 pins female DB connector)
A and B relays change when CSS 204 goes on alarm.
C relay gives information on missing signal even when switch 4 is disabled.
Mind, C relay, does not necessarily means that an alarm occurred.
F -
Remote control input for "Alarm disable" and "Master B remote" (15 pins female DB connector)
"Alarm disable" forbids CSS 204 to go on alarm. Switch 15 to enforce alarm is always operative.
"Master B remote" allows remotely switching the monitoring to B input.
ALARM DISABLE
1
+ VCC
9
+ OPTO
2
- OPTO
GND
10
Example for Alarm disable input :
1
link
9
2
Dry Loop
10
G -
CEI power supply connector
ENGLISH
Serial Nbr
A=ALARM(relay 1)
1
+ VCC
B=ALARM(relay 2)
9
+ OPTO
C=BLANK DETECT
2
- OPTO
GND
10
3
+ VCC
11
+ OPTO
4
- OPTO
REMOTE INPUT
12
GND
A
B
C
MASTER (B) REMOTE
3
+ VCC
11
+ OPTO
4
- OPTO
12
GND
Dry loop
or
link
10
A
B
C
1
ALARM RELAY
RIGHT
LEFT
OUTPUT
OUTPUT
Remote inputs use opto couplers, thus allowing
driving CSS204 with any kind of equipment (Dry
contact loops, voltage, or open collector).
1
9
Voltage
or
2
(5V ~ 24V)
18
PUSH
PUSH
PUSH
PUSH
RIGHT
LEFT
RIGHT
LEFT
MASTER (B) INPUT
MASTER (A) INPUT
2
1: GND
2: Hot Pt
3: Cold Pt
1
1
9
Collector Output
or
2
10
RIGHT
LEFT
SAVE INPUT
PUSH
1
3
2
3
1
link
9
2
10
Rami - CSS 204