Télécharger Imprimer la page

Sagi KBPZ163A Manuel D'utilisation Et D'installation page 24

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
disorders and sudden death. Product mists or sprays may
cause ice burns of eyes and skin.
4) First aid procedures
Inhalation:
keep injured person away from exposure, warm and relaxed.
Use oxygen, if necessary. Give artificial respiration if
respiration has stopped or is about to stop. In case of cardiac
arrest give external cardiac massage. Seek immediate medical
attention.
Skin:
use water to remove ice from affected areas. Remove
contaminated clothes.
CAUTION: clothes may adhere to skin in case of ice burns.
In case of contact with skin, wash with copious quantities of
lukewarm water. In case of symptoms (irritation or blisters)
seek medical attention.
Eyes:
immediately wash with ocular solution or fresh water, keeping
eyelids open for at least 10 minutes. Seek medical attention.
Ingestion:
it can cause vomit.. If conscious, rinse mouth with water and
drink 200-300 ml of water. Seek medical attention.
Other medical treatment:
symptomatic treatment and support therapy when indicated.
Do not administer adrenaline or sympatheticomimetic drugs
after exposure, due to the risk of arrhythmia and possible
cardiac arrest.
5) Environmental data
Persistence and degradation
HFC 143a:
slow decomposition in lower atmosphere (troposphere).
Duration in atmosphere is 55 years.
HFC 125:
slow decomposition in lower atmosphere (troposphere).
Duration in atmosphere is 40 years.
HFC 134a:
relatively rapid decomposition in lower atmosphere
(troposphere). Duration in atmosphere is 15.6 years.
HFC 143a, 125, 134a:
does not affect photochemical smog (not included in volatile
organic components – VOC – as established in the UNECE
agreement). Does not cause ozone rarefaction.
Product exhausts released in the atmosphere do not cause
long-term water contamination.
The wiring diagram is shown on the last page of this manual.
POS:
DESCRIPTION
1
COMPRESSOR
2
CONDENSER FAN
3
TERMINAL BOARD
6
MAIN SWITCH
8
PLUG
9
EVAPORATOR FUN
69
GROUNDING TERMINAL
88
DIGITAL THERMOREGULATOR
13

Publicité