NOTE: Remote control cannot be used to reset CHECK FILTER timer.
6.3.3 Battery Installation/Replacement
a. On the back of the remote use your thumbnail or a coin to gently pry the battery cover locking tab
open to remove the battery cover and gain access to the battery compartment.
b. Be sure to correctly install the batteries in the proper orientation as indicated on the inside back
panel of the battery compartment.
c. Reinstall battery cover by first inserting orientation tabs on cover into body of remote and then
gently closing cover until lock tab engages.
NOTE: Using force or rough handling of battery cover can break-off locking tab.
7. OPERATING MODES

MANUAL Mode

7.1.
Your air purifier has four different fan speeds to choose from. By pressing the FAN SPEED button, you can cycle
through the speeds to achieve the desired setting. Each speed is indicated by a different icon in the LED Display
(M) and a different coloured ring around the Power Button(K) with Green = Quiet, Blue = Low, Orange =
Medium, and Red = High.

TIMER Mode

7.2.
Your air purifier is equipped with a programmable shut-off timer. By pressing TIMER button, you can cycle
the shut-off timer in 1 hour increments to a maximum of 12 hours. The LED Display indicates the number
of hours selected. To cancel the timer, once you reach 12 hours, press the TIMER button once more, the
timer will disappear.

AUTO Mode

7.3.
In AUTO Mode the unit automatically adjusts the fan speed based on the ambient air quality as detected by
the dust and odor sensors. As the presence of contaminants increase, the unit's fan speed will increase,
and as the air quality improves, the fan speed will decrease. In AUTO Mode both the germicidal ultraviolet
lamps and the photocatalytic oxidation chamber are working by default. To activate AUTO Mode, press the
AUTO button on the control panel once. The AUTO icon will illuminate to show that AUTO Mode has been
activated. To switch to MANUAL Mode from AUTO Mode, press the AUTO or FAN SPEED button, the
AUTO indicator will go out and the unit is now in MANUAL Mode.
8. MAINTENANCE

FILTER CLEANING

8.1.
To ensure optimal operation and efficiency of your Asept-Air Life Cell air purifier, you should check filters
bi-weekly, clean them quarterly and replace them annually. If your indoor air quality is particularly dusty or
contaminated, you may need to check, clean and replace the filters more frequently. Failure to check,
clean and replace the filters regularly will restrict airflow, reduce efficiency and shorten the life-span of your
air purifier.
8.1.1 Washable Prefilter – After removing the Front Panel, see section 0, gently vacuum the front (dirty) surface
of the prefilter using the dusting brush attachment to remove as much of the trapped dust as possible. You
can then remove this filter, see section 8.4.1. and take it outside to shake then thoroughly rinse from the
back (clean) side under a kitchen faucet or with the garden hose. Lay flat or hang to dry. DO NOT
machine wash or put in dryer. Inspect every 2 weeks, Clean every 3 months, and replace annually,
or as required.
8.1.2 HEPA/Carbon Filter – With the prefilter removed use the vacuum cleaner to gently vacuum the facing
surface of the filter using the dusting brush attachment. DO NOT WET THIS FILTER Inspect every 2
weeks, Clean every 3 months, and replace annually, or as required.
8.1.3 Ultraviolet Lamps – With the HEPA/Carbon filter removed carefully remove each UV lamps by gently
twisting counter clockwise, towards you, until lamp pins are aligned with socket slot and lamps can be
removed by pulling straight out towards you. Wipe each lamp tube with a slightly dampened cloth and dry
fully before reinserting into socket. Inspect every 2 weeks, Clean every 3 months, and replace annually.
ALWAYS handle UV lamps with care as they are fragile like any other light bulb.
8.1.4 Photocatalytic Oxidation Chamber (PCO) – With the UV lamps removed, use the vacuum cleaner to
gently vacuum the metal mesh surface using the dusting brush attachment. DO NOT WET THIS
ELEMENT. Inspect every 2 weeks and clean every 3 months, or as required. This element is
permanent and does not need regular replacing.
CONTROL PANEL AND HOUSING CLEANING
8.2.
1.
ALWAYS unplug the unit from its power source before performing any maintenance.
2.
Remove dust and dirt by gently vacuuming using a dusting brush attachment. Wipe down surfaces with a
lint-free cloth slightly dampened with dish soap and water.