General; Recommended Spare Parts, Spare Pumps; Spare Parts; Stand-By Pumps - ITT VOGEL L Série Instructions De Montage, De Service Et De Maintenance

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation, Operating and Maintenance Instruction

8.2 General

Carry out disassembly and mounting according to the
appropriate sectional drawing (at the appendix).
You will only need common tools.

9. Recommended Spare Parts, Spare Pumps

9.1 Spare Parts

Spare parts should be selected to last for two-year
continuous operation. If no other guidelines are
applicable, we recommend that you stock the number
of parts listed below (in accordance with DIN 24296).
2
Spare Parts
Impeller
1
Shaft with key and nuts
1
Ball Bearing
set
1
Joints for pump casing
4
sets
other joints
sets
4
Mech. Seals
set
1
Bearing (lantern with
bearing bracket,
-
complete with shaft,
bearings, aso.)
To ensure optimum availability, we recommend
that suitable quantities of spare parts are held in
stock, especially if these are made from special
materials and in the case of mechanical seals,
because of the longer delivery times.
Spare Parts Order
When ordering spare parts, please supply the
following information:

10. Faults - Causes and Solutions

The following notes on causes of faults and how to
repair them are intended as an aid to recognising the
problem.
The
manufacturer's
Department is available to help repair faults that the
operator cannot or does not want to repair. If the
LN 100-ger/fr/eng
Artikel No. 771073301
Number of pumps
(incl. stand-by pumps)
3
4
5
6/7
8/9
Number of Spare Parts
1
1
2
2
2
1
1
2
2
2
1
2
2
2
3
6
8
8
9
12 150%
6
8
8
9
10 100%
1
2
2
2
3
-
-
-
-
-
Customer
Service
Page 60
Before disassembly check if required parts are ready.
Disassemble the pump only so far, as required for the
replacement of the repair part.
Type:
______________________________________________________________________
S/N (Order No.):
Part name:
Sectional Drawing
All the information is given in the data sheet and the
relevant sectional drawing.
10/+
Store spare parts in dry and clean rooms!
20%
20%
25%

9.2 Stand-by pumps

It is essential that a sufficient number of stand-
25%
by pumps are kept ready for use in plants where
failure of a pump could endanger human life or
2
cause damage to property or high costs.
Regular checks should be carried out to ensure
that such pumps are always ready for use (see
chapter 6.8).
Store stand-by pumps according to chapter 6.8.
operator repairs or changes the pump, the design data
on the Data Sheet and chapter 2 of these Operating
Instructions should be particularly taken into account.
If
necessary,
manufacturer must be obtained.
Model L, LN
___________________________________________________
_
_____________________________________________________________
__________________________________________________
the
written
agreement
of
the
Revision 02
Issue 10/2006

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vogel ln série

Table des Matières