Weather-compensated heating control
(heating control with integrated tank
temperature controller and tank tem-
perature sensor)
Electrical auxiliary heating system
E2 / E4.5 / E6
Electrical auxiliary heating system
14

Controller for charging pump

Insert the electronic tank temperature sensor of the heating control into the upper im-
mersion sleeve for the tank sensor of the heater and fasten with the sensor bracket.
For tanks with a sensor channel, push the sensor in vertically as far as it will go. Set
desired tank temperature at the tank temperature controller of the heating control.
(max. 60°C).
Electrical auxiliary heating system 2 kW/230V~, 4.5 kW/400 V~, 6 kW/400 V~.
with integrated tank temperature controller and safety temperature limiter.
Screw electrical auxiliary heating system into the 1 ½" pipe coupling at the solar tank
and seal it.
The rules and regulations of the VDE and the local energy supply companies must be
observed.
The connection must be performed by a licensed electrician.
Disconnect power before opening devices! Never touch live components - risk
of injury or even death!
Unscrew the lid of the electrical auxiliary heating system and connect to the mains 230
or 400 V~ according to the enclosed instructions. Connecting wire must be provided
on site.